HMF Series 8 Version - 0
3. Specification
Model Indoor Unit
AWSI-HMF009-N12
Model Outdoor Unit
AWAU-YMF009-C12
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Capacity
(1)
Btu/h
8600
EER /COP
(2)
W/W
2.65
Power supply
V/Ph/Hz
220-230V/Single/60Hz
Circuit breaker rating
A
16
INDO
O
R
Fan type & quantity
Cross flow fan x1
Fan speeds
H/M/L
RPM
1200 / 950 / 800
Air flow
(3)
H/M/L
m3/hr
470/370/310
External static pressure
Min-Max
Pa
0
Sound pressure level
(5)
H/M/L
dB(A)
41/34/31
Moisture removal
l/hr
1.0
Condensate drain tube I.D
mm
16
Dimensions
WxHxD
mm
715x188x250
Weight
kg
6.5
Package dimensions
WxHxD
mm
775x260x324
Packaged weight
kg
8.5
O
UTDO
O
R
Refrigerant control
Capillary
Compressor type, model
ROTARY
Fan type & quantity
Axial x 1
Fan speeds
H/L
RPM
1015
Air flow
H/L
m3/hr
1400
Sound pressure level
(5)
H/L
dB(A)
55
Dimensions
WxHxD
mm
685x260x430
Weight
kg
19.5
Package dimensions
WxHxD
mm
795x345x495
Packaged weight
kg
21
Refrigerant type
R410A/380g
Refrigerant charge (standard connecting tubing length)
kg(5m)
0.59
Additional charge per 1 meter
gr / 1m
20
Connections between units
Liquid line
In.(mm)
1/4"(6.35)
Suction line
In.(mm)
3/8" (9.52)
Max.tubing length
m.
20
Max.height difference
m.
8
Operation control type
Remote control
Heating elements
kW
Others
Содержание AWAU-YMF009-C12
Страница 16: ...HMF Series 16 Version 0 6 Wiring Diagram 6 1 Indoor Unit AWSI HMF009 N12 AWSI HMF012 N12 AWSI HMF018 N12...
Страница 17: ...HMF Series 17 Version 0 AWSI HMF024 N12 6 2 Outdoor Unit AWAU YMF009 C12 AWAU YMF012 C12...
Страница 18: ...HMF Series 18 Version 0 AWAU YMF018 C12 AWAU YMF024 C12...
Страница 19: ...HMF Series 19 Version 0...
Страница 50: ...HMF Series 50 Version 0 AWSI HMF012 N12 ONLY FOR STANDARD BOM CUSTOMIZED FEATURE MAY CHANGE THE PART LIST...
Страница 52: ...HMF Series 52 Version 0 ONLY FOR STANDARD BOM CUSTOMIZED FEATURE MAY CHANGE THE PART LIST...
Страница 58: ...HMF Series 58 Version 0 AWAU YMF012 C12 ONLY FOR STANDARD BOM CUSTOMIZED FEATURE MAY CHANGE THE PART LIST...
Страница 60: ...HMF Series 60 Version 0 AWAU YMF018 C12 ONLY FOR STANDARD BOM CUSTOMIZED FEATURE MAY CHANGE THE PART LIST...
Страница 62: ...HMF Series 62 Version 0 AWAU YMF024 C12 ONLY FOR STANDARD BOM CUSTOMIZED FEATURE MAY CHANGE THE PART LIST...
Страница 64: ...HMF Series 64 Version 0 SERVICE MANUAL HMF Series...