HMF Series 10 Version - 0
Model Indoor Unit
AWSI-HMF018-N12
Model Outdoor Unit
AWAU-YMF018-C12
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Capacity
(1)
Btu/h
17500
EER /COP
(2)
W/W
2.62
Power supply
V/Ph/Hz
220-230V/Single/60Hz
Circuit breaker rating
A
16
INDO
O
R
Fan type & quantity
Cross flow fan x1
Fan speeds
H/M/L
RPM
1280 / 1100 / 950
Air flow
(3)
H/M/L
m3/hr
750/640/560
External static pressure
Min-Max
Pa
0
Sound pressure level
(5)
H/M/L
dB(A)
44/40/36
Moisture removal
l/hr
1.8
Condensate drain tube I.D
mm
16
Dimensions
WxHxD
mm
940x205x275
Weight
kg
10
Package dimensions
WxHxD
mm
1015x265x350
Packaged weight
kg
12.5
O
UTDO
O
R
Refrigerant control
Capillary
Compressor type, model
ROTARY
Fan type & quantity
Axial x 1
Fan speeds
H/L
RPM
1070
Air flow
H/L
m3/hr
2000
Sound pressure level
(5)
H/L
dB(A)
48
Dimensions
WxHxD
mm
780x250x540
Weight
kg
30.5
Package dimensions
WxHxD
mm
910x335x585
Packaged weight
kg
32
Refrigerant type
R410A/580g
Refrigerant charge (standard connecting tubing length)
kg(5m)
1.6
Additional charge per 1 meter
gr / 1m
40
Connections between units
Liquid line
In.(mm)
1/4(6.35)
Suction line
In.(mm)
1/2"(12.7)
Max.tubing length
m.
20
Max.height difference
m.
8
Operation control type
Remote control
Heating elements
kW
Others
Содержание AWAU-YMF009-C12
Страница 16: ...HMF Series 16 Version 0 6 Wiring Diagram 6 1 Indoor Unit AWSI HMF009 N12 AWSI HMF012 N12 AWSI HMF018 N12...
Страница 17: ...HMF Series 17 Version 0 AWSI HMF024 N12 6 2 Outdoor Unit AWAU YMF009 C12 AWAU YMF012 C12...
Страница 18: ...HMF Series 18 Version 0 AWAU YMF018 C12 AWAU YMF024 C12...
Страница 19: ...HMF Series 19 Version 0...
Страница 50: ...HMF Series 50 Version 0 AWSI HMF012 N12 ONLY FOR STANDARD BOM CUSTOMIZED FEATURE MAY CHANGE THE PART LIST...
Страница 52: ...HMF Series 52 Version 0 ONLY FOR STANDARD BOM CUSTOMIZED FEATURE MAY CHANGE THE PART LIST...
Страница 58: ...HMF Series 58 Version 0 AWAU YMF012 C12 ONLY FOR STANDARD BOM CUSTOMIZED FEATURE MAY CHANGE THE PART LIST...
Страница 60: ...HMF Series 60 Version 0 AWAU YMF018 C12 ONLY FOR STANDARD BOM CUSTOMIZED FEATURE MAY CHANGE THE PART LIST...
Страница 62: ...HMF Series 62 Version 0 AWAU YMF024 C12 ONLY FOR STANDARD BOM CUSTOMIZED FEATURE MAY CHANGE THE PART LIST...
Страница 64: ...HMF Series 64 Version 0 SERVICE MANUAL HMF Series...