CONTROL
SYSTEM
The SPT will be adjusted according to following chart.
Press either Sleep button or ON/OFF button can cancel the Sleep function.
Sleep function will not be available in Auto mode or Fan mode.
11.10
I-Feel function
I-Feel function maintains the room temperature by comparing the RCT on remote control.
Pressing IFEEL button will enable the I-Feel function.
will be shown on remote control.
Under I-Feel funtion, remote control sends I-Feel data every 10 min to IDU controller. If the IDU
controller does not received I-Feel data after 11 min. I-Feel function will be interrupted and then the
AC will work according to RAT on the IDU.
I-Feel function can not be remembered after power failure.
11.11
8-degree heating mode
Under heat mode, press “Eco” button, the system will enter into 8 Degree Heat Mode.
1. 8 Degree Heat Mode can not exist together with Sleep mode. If Sleep Mode is selected, 8
degree Heat Mode will be canceled.
2. The SPT will be 8 degree and display will show the SPT,
3.
Under this mode, IFAN can not be changed manually (Including Turbo speed)
4.
Under this mode, IFAN will operate as following table when compressor is ON. When
compressor stops, IFAN will operate as “
Residual heat blowing function” (refer to 11.4.1)
Indoor Fan speed
High
Medium
Low
RAT
<=9
(9,11) >=11
One speed should keep at least 210sec operating before switching to other speeds.
11.12
Protections
There are 4 protection codes.
Normal (Norm) – unit operate normally.
Stop Rise (SR) – compressor frequency can not be raised but does not have to be decreased.
HzDown – Compressor frequency is reduced by 2Hz/s
11-8
SM HGD-009/012 1-A.1 GB
Stop Compressor (SC) – Compressor is stopped.
Содержание AWAU-YGD009-H11
Страница 10: ...OUTLINE DIMENSION 4 OUTLINE DIMENSION 4 1 Indoor HGD009 012 4 2 Outdoor YGD009 SM HGD 009 012 1 A 1 GB 4 1 ...
Страница 11: ...OUTLINE DIMENSION 4 3 Outdoor YGD012 4 2 SM HGD 009 012 1 A 1 GB ...
Страница 24: ...WIRING DIAGRAMS 8 3 YGD009 8 4 YGD012 8 2 SM HGD 009 012 1 A 1 GB ...
Страница 25: ...REFRIGERATION DIAGRAM 9 REFRIGERATION DIAGRAMS 9 1 HGD009 YGD009 9 2 HGD012 YGD012 SM HGD 009 012 1 A 1 GB 9 1 ...
Страница 50: ...EXPLODED VIEW SPARE PART LIST 13 4 Exploded view of outdoor unit YGD009 13 4 SM HGD 009 012 1 A 1 GB ...
Страница 52: ...EXPLODED VIEW SPARE PART LIST 13 6 Exploded view of outdoor unit YGD012 13 6 SM HGD 009 012 1 A 1 GB ...
Страница 54: ...APPENDIX SM HDD HED 009 012 1 A 1 GB 13 1 APPENDIX ...