Electrical Control Function
148
Electrical Control System
38
EXV open angle for B indoor unit
If the value is higher than 99, the digital display tube will show single
digit and tens digit.
For example ,the digital display tube show “2.0”,it means the EXV
open angle is 120×4=480p.)
39
EXV open angle for C indoor unit
40
EXV open angle for D indoor unit
41
EXV open angle for E indoor unit
42
Frequency limit symbol
Bit7
Frequency limit caused by IGBT
radiator
The display value
is hex number. For
example, the
digital display tube
show 2A,then
Bit5=1, Bit3=1,
Bit1=1.
It means
frequency limit
caused by T4,T3
and current.
Bit6
Frequency limit caused by PFC
Bit5
Frequency limit caused by T4.
Bit4
Frequency limit caused by T2.
Bit3
Frequency limit caused by T3.
Bit2
Frequency limit caused by T5
Bit1
Frequency limit caused by current
Bit0
Frequency limit caused by voltage
43
Average value of T2
(Sum T2 value of all indoor units)/( number of indoor units in good
connection)
44
Outdoor unit fan motor state
Off:0, High speed:1, Med speed:2, Low speed:3 Breeze:4, Super
breeze:5
45
The last error or protection code
00 means no malfunction and protection
The following items from 1.3.12.1 to 1.3.12.5 are for the explanation of the point check functions.
1.3.12.1
Frequency of compressor:
Display
Frequency of compressor (Hz)
30
30
--
Stand by
60
60
1.3.12.
2 Running mode:
Display
Corresponding mode
0
Off
1
Fan only
2
Cooling mode
3
Heating mode
4
Forced cooling
1.3.12.
3 Capacity demand:
Cooling mode
T1 Ts
3
1
1
e
c
a
4
2
0
2
3
0
1
f
d
b
Capacity area
a
b
c
d
e
f
Norm value (N)
3
2
1.5
1
0.5
0
Heating mode
Содержание AWAU-YCZ218-H11
Страница 24: ...Dimensions Outdoor Units 97 AWAU YCZ536 H11...
Страница 28: ...Wiring Diagrams Outdoor Units 101 4 Wiring Diagrams AWAU YCZ218 H11 7SP091166 AWAU YCZ218 H11 7SP091170...
Страница 29: ...Wiring Diagrams 102 Outdoor Units AWAU YCZ327 H11 7SP091167 AWAU YCZ327 H11 7SP091171...
Страница 30: ...Wiring Diagrams Outdoor Units 103 AWAU YCZ430 H11 7SP091168 AWAU YCZ430 H11 7SP091172...
Страница 31: ...Wiring Diagrams 104 Outdoor Units AWAU YCZ536 H11 7SP091169 AWAU YCZ542 H11 7SP091173...
Страница 37: ...Exploded View and Spare Part list 110 Outdoor Units Exploded view of model AWAU YCZ218 H11 7SP091170...
Страница 39: ...Exploded View and Spare Part list 112 Outdoor Units Exploded View of outdoor unit AWAU YCZ327 H11 7SP091167...
Страница 41: ...Exploded View and Spare Part list 114 Outdoor Units Exploded view of model AWAU YCZ327 H11 7SP091171...
Страница 43: ...Exploded View and Spare Part list 116 Outdoor Units Exploded View of outdoor unit AWAU YCZ430 H11 7SP091168...
Страница 45: ...Exploded View and Spare Part list 118 Outdoor Units Exploded View of outdoor unit AWAU YCZ430 H11 7SP091172...
Страница 47: ...Exploded View and Spare Part list 120 Outdoor Units Exploded View of outdoor unit AWAU YCZ536 H11 7SP091169...
Страница 49: ...Exploded View and Spare Part list 122 Outdoor Units Exploded View of outdoor unit AWAU YCZ542 H11 7SP091173...
Страница 107: ...SERVICE MANUAL Multi Splits Series...