Troubleshooting
Electrical Control System
163
2.4.2 For the outdoor unit
2.4.2 1 Outdoor EEPROM malfunction(ODU E0)
If the EEPROM chip
is welded on PCB,
replace the PCB
directly. Otherwise,
check whether the
EEPROM chip
plugged in PCB well?
Yes
No
Yes
Insert the EEPROM well
Replace the outdoor main board
Outdoor EEPROM malfunction
Содержание AWAU-YCZ218-H11
Страница 24: ...Dimensions Outdoor Units 97 AWAU YCZ536 H11...
Страница 28: ...Wiring Diagrams Outdoor Units 101 4 Wiring Diagrams AWAU YCZ218 H11 7SP091166 AWAU YCZ218 H11 7SP091170...
Страница 29: ...Wiring Diagrams 102 Outdoor Units AWAU YCZ327 H11 7SP091167 AWAU YCZ327 H11 7SP091171...
Страница 30: ...Wiring Diagrams Outdoor Units 103 AWAU YCZ430 H11 7SP091168 AWAU YCZ430 H11 7SP091172...
Страница 31: ...Wiring Diagrams 104 Outdoor Units AWAU YCZ536 H11 7SP091169 AWAU YCZ542 H11 7SP091173...
Страница 37: ...Exploded View and Spare Part list 110 Outdoor Units Exploded view of model AWAU YCZ218 H11 7SP091170...
Страница 39: ...Exploded View and Spare Part list 112 Outdoor Units Exploded View of outdoor unit AWAU YCZ327 H11 7SP091167...
Страница 41: ...Exploded View and Spare Part list 114 Outdoor Units Exploded view of model AWAU YCZ327 H11 7SP091171...
Страница 43: ...Exploded View and Spare Part list 116 Outdoor Units Exploded View of outdoor unit AWAU YCZ430 H11 7SP091168...
Страница 45: ...Exploded View and Spare Part list 118 Outdoor Units Exploded View of outdoor unit AWAU YCZ430 H11 7SP091172...
Страница 47: ...Exploded View and Spare Part list 120 Outdoor Units Exploded View of outdoor unit AWAU YCZ536 H11 7SP091169...
Страница 49: ...Exploded View and Spare Part list 122 Outdoor Units Exploded View of outdoor unit AWAU YCZ542 H11 7SP091173...
Страница 107: ...SERVICE MANUAL Multi Splits Series...