General warnings

Fundamental safety rules

  After unpacking, check that the contents are intact and that 

all parts are included. If not, contact the agent who sold the 
appliance to you.

  The appliance must be installed by an authorised company. 

Once the work is done, it must issue a declaration of conformity 
to the client in compliance with current regulations and with 
the indications in the instruction manual supplied y the 
manufacturer with the appliance

  These appliances have been designed for conditioning and/

or heating rooms and they must be destined solely for this 
purpose, in accordance with their performance characteristics.

 

The manufacturer refuses any contractual or extra-contractual 
liability for damage caused to people, animals or property 
resulting from incorrect installation, adjustment, maintenance 
or improper use.

   

In the event of water leaks, turn off the main switch and 

close the water taps.

 

Immediately call the Technical Assistance Service or other 
qualified personnel and do not intervene personally on the 
appliance.

  A temperature that is too high or too low is harmful to health 

and is an unnecessary waste of energy.

 

Avoid prolonged direct contact with the air flow.

  Do not leave the room closed for long. Periodically open the 

windows to ensure proper ventilation.

  

This instruction booklet is an integral part of the 

appliance and, therefore, it must be kept with care and must 
ALWAYS accompany the appliance, even when the latter is 
transferred to another owner or user or transferred to another 
system.

 

If it gets damaged or lost, please request another copy from 
the local Technical Assistance Service.

  Repairs or maintenance must be performed by the Technical 

Assistance Service or by qualified personnel in accordance 
with this manual.

 

Do not modify or tamper with the appliance as this could 
create dangerous situations and the manufacturer will not be 
liable for any damage caused.

 

The appliance is declared to have an IPX0 protection rating, 
therefore, it cannot be installed outdoors or in laundry rooms.

  The use of products that use electricity and water requires the 

observation of some fundamental safety rules such as:

  The unit can be used by children over the age of 8, and by 

people with reduced physical, sensory or mental capabilities, 
or with no experience or necessary knowledge, as long as 
they are monitored or after they have received instructions 
on the safe use of the unit and have understood the dangers 
involved.

 

Children must not play with the appliance.

 

The cleaning and maintenance that must be performed by the 
user should not be carried out by children without supervision.

  It is forbidden to modify the safety or adjustment devices 

without authorisation from and indications of the 
manufacturer.

It is forbidden to pull, remove or twist the electric cables coming 

out of the unit, even when disconnected from the mains 
power supply.

  It is forbidden to introduce objects or substances through the 

aspiration grills and the air outflow.

  It is forbidden to open the access doors to the internal parts 

of the appliance without having turned off the main switch 
first or disconnecting the appliance from the electrical power 
supply.

  It is forbidden to dispose of, or leave in the reach of children, 

the packaging materials which could become a source of 
danger.

  It is forbidden to climb onto the appliance and/or to place any 

type of object on top of it.

GENERAL

Содержание AW-XDO009-H11

Страница 1: ...XDO Direct expansion console water source DC Inverter technology Silent heat pump EN Installation manual...

Страница 2: ...ronic equipment 2011 65 EC RoHS2 Waste electrical and electronic equipment 2012 19 EC WEEE Energy consumption indication on the labels of energy related products 2010 30 EU ErP Directive 2009 125 EC a...

Страница 3: ...parts 2 Installation Installation method Choosing the position of the unit Assembling the unit Condensation drain preparation Mounting the appliance on the bracket Hydraulic connection Electrical con...

Страница 4: ...l Technical Assistance Service Repairs or maintenance must be performed by the Technical Assistance Service or by qualified personnel in accordance with this manual Do not modify or tamper with the ap...

Страница 5: ...n a high or low position Everything that is required for installation assembly template support brackets except for the drill of course is contained in the packaging Remote control and on board touch...

Страница 6: ...attery Installation manual Handling The unit is packed singularly in a cardboard box Boxes can either be carried singularly by hand by two operators or loaded on a forklift truck for a maximum of thre...

Страница 7: ...s Air outlet flaps Touch screen display Front panel Water input Eurokonus M 3 4 Water output Eurokonus M 3 4 Internal air intake grille Air Filter Anti lifting bracket Room air probe Power supply term...

Страница 8: ...avoid malfunctions or dangerous situations the location of the unit must meet the following requisites Respect the minimum distances indicated in the diagram The wall on which you intend to anchor the...

Страница 9: ...w density place a bracket if necessary on the outside that can support the appliance safely The manufacturer cannot be held responsible for any underestimation of the structural consistency of the anc...

Страница 10: ...t is necessary to add a siphon before placing the pipe into the main drain This siphon must be placed at least 300 mm under the mouth of the appliance If the line flows into a container e g a tank do...

Страница 11: ...les sand rust slag or any foreign bodies that may damage the system It is advisable to provide a by pass in the system in order to be able to wash the exchanger without having to disconnect the applia...

Страница 12: ...ces to be integrated for safety KEY TO SYMBOLS 1 Temperature probe 2 Anti vibration joint 3 Exhaust valve 4 Mesh filter 5 6 Shut off valve 7 Safety valve 8 Expansion tank for pressure surges 9 Flow sw...

Страница 13: ...characteristics of water During the initial start up the specialised technician must measure the system water reference values using the special test kits System water reference values pH Electrical c...

Страница 14: ...ith suitable protections against overloads and or short circuits using a 10 Amp Time delay fuse or other equivalent devices is recommended To prevent any risk of electrocution always disconnect the ma...

Страница 15: ...to a free non live contact the appliance is put is stand by and CP appears on the display Using this contact it is possible to connect an external device that inhibits the functioning of the applianc...

Страница 16: ...the lower hole Remove the upper grill Remove the two plastic side panels by moving them up Unscrew the fixing screws Remove the front panel Place the bottom cover and fix it with the supplied screws o...

Страница 17: ...he night button for 10 seconds ds disabled or En enabled will appear on the display Open CP contact Touch screen display key lock Hotel function Display indications Cause E1 Faulty room temperature RT...

Страница 18: ...lop or where there are humidity and temperature conditions that exceed the maximum levels reported on the installation manual Clean the air filter regularly as described in the specific paragraph Befo...

Страница 19: ...o start up the appliance after a period of inactivity NB before performing any operation take care with the hot and or sharp surfaces of the metal The filter is located in the top part of the applianc...

Страница 20: ...ncreased for example a door or a window has been left open or an appliance has been installed in the room which generates a lot of heat Try to reduce the heating and cooling load of the room following...

Страница 21: ...cooling mode 45 C Minimum operating temperature in cooling mode 7 C Maximum operating temperatures in heating mode 40 C Minimum operating temperatures in heating mode 7 C Operating limits Technical sp...