INSTALLATION
The unit can be installed either in the lower part (near the
floor) or in the upper part (near the ceiling) of the wall.
In order to optimise air distribution and comfort, the
direction of the air flow can be modified by adjusting the
position of the air flap.
The appliance is supplied ready to be installed in the lower
part of the wall, so the air flow is directed upwards.The same
configuration can also be used in the upper part of the wall
in cooling mode, which increases the air flow in the room
(coanda effect).
In this case, purchase the lower cover decorative kit code
GB0737.
This operation must be performed while the appliance
is switched off and disconnected.
-
Open the air outlet flap gently
-
Remove the flap opening block insert located internally
on the right of the air outlet mouth and place it in the
lower hole.
-
Remove the upper grill
-
Remove the two plastic side panels by moving them up
-
Unscrew the fixing screws
-
Remove the front panel
- Place the bottom cover and fix it with the supplied
screws (optional kit GB0737)
-
Refit in the reverse order.
After adjusting the air outlet flap position, it is necessary to
set up the electronic control of the appliance:
- Keep pressed the
button on the display for 5 seconds;
- The dn (lower wall) symbol flashes on the display;
- Press the
key again;
- The uP (upper wall) symbol lights up on the display.
- If no other operations are performed in the following 2
seconds, the new setting is memorised.
For the appliance to work properly, each time the
configuration of the air outlet flap is modified, the electronic
control must be set.
Modification from lower wall to the upper wall installation
High installation
Low installation (factory settings)
Block insert
Lower cover (kit code GB0737)
Fixing screws (supplied with the optional kit GB0737)
Upper grill
Plastic side panels
Front panel
High/low installation configuration