AIRSTREAM CLASSIC TRAILER
110 Breaker Panels
30 amps Service
, Exterior Outlet, Dinette,
Circuit 7, 20 Amps, Bedroom TV
Airstream installs a ground fault circuit interrupter to
owever, the shock should be of such short duration that the effects would be reduced to less than the
Circiut1, 20 amps A/C
Circuit 2, 20 amps, Bedroom, converter
Circuit 3, 15 amps, Water Heater
Circuit 4, 20 amps, Microwave
Circuit 5, GFI, Galley, Lavatory
Lounge
50 Amp Service (Different Panel)
Circiut1, 15 amps Water Heater
Circuit 2, 20 amps, Front A/C, Bedroom,
Circuit 3, 20 amps, Converter
Circuit 4, 20 amps, Microwave
Circuit 5, GFI, Galley, Lavatory, Exterior Outlet, Dinette,
Lounge
Circuit 6, 20 Amps, Rear A/C
The breaker panel in your trailer has a label installed to designate circuit specific to the trailer.
GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
protect several outlets on the trailer.
When properly installed, the GFCI circuit breaker
provides reliable overload and short circuit protection
PLUS protection from Ground Faults that might
result from contact with a "HOT"' load wire and
ground.
IMPORTANT NOTE:
The GFCI circuit breaker
will NOT reduce shock hazard if contact is made
between a "HOT" load wire and a neutral wire or 2
"HOT" load wires.
Each GFCI circuit breaker is calibrated to trip with a
ground current of 5 milliamperes or more. Since most
persons can feel as little as 2 milliamperes, a distinct shock may be felt if the need for protection exists.
H
normally dangerous level. However, persons with acute heart problems or other conditions that can make a
person particularly susceptible to electric shock may still be seriously injured.
While the GFCI circuit breaker affords a high degree of protection, there is no substitute for the knowledge
that electricity can be dangerous when carelessly handled or used without reasonable caution.
G-16
Содержание Classic Trailer 25' 2005
Страница 1: ...AIRSTREAM AN AMERICAN LEGEND CLASSIC TRAILER OWNERS MANUAL 2005...
Страница 2: ......
Страница 14: ...AIRSTREAM CLASSIC TRAILER A 9 MAINTENANCE RECORD DATE DEALER SERVICE PERFORMED...
Страница 15: ...AIRSTREAM CLASSIC TRAILER A 10 NOTES...
Страница 33: ...AIRSTREAM CLASSIC TRAILER B 18 NOTES...
Страница 39: ...AIRSTREAM CLASSIC TRAILER C 6 NOTES...
Страница 58: ...AIRSTREAM CLASSIC TRAILER D 16 OTES N...
Страница 72: ...AIRSTREAM CLASSIC TRAILER F 5 YPICAL GAS LINE SYSTEM T...
Страница 112: ...AIRSTREAM CLASSIC TRAILER 110 VOLT LAYOUTS Bedroom outlets will vary to twin or double bed models G 18...
Страница 113: ...AIRSTREAM CLASSIC TRAILER G 19...
Страница 124: ...Notes...
Страница 125: ......
Страница 126: ......