ELECTRICAL
G - 8
G
G - 9
MONITOR PANEL
Micropulse Systems Monitor
CATCON PRODUCTS INC.
817-921-2188
The MicroPulse System makes use of a single solid-state sensor per tank. The
MicroPulse sensor measures the static (head) pressure at the bottom of the tank
and transmits this information to the MicroPulse System Monitor. Knowing this
pressure value, after a one-time calibration has been performed, the MicroPulse
System will calculate and accurately display the tank level in 1/8 increment.
A single sensor is installed on the sidewall of each tank, near the bottom, via a
3/4” female NPT spin-in thread. The sensor is solid state, there are no moving
parts to wear or maintain. Because the principle of operation does not involve
any electrical current flow through the tanks contents (conducted or induced),
the nature of the fluid in the tank is unimportant.
The monitor system has been calibrated at the factory and should never need
another calibration. If you feel the system is not operating correctly, please
contact CATCON Products or a local Airstream dealer. The following instruc-
tions are provided for qualified service technicians.
MICROPULSE SYSTEMS MONITOR OPERATION INSTRUCTIONS
This example shows the monitor reporting the following:
Monitor Display
Fresh Water
Gray
Water 1
Gray
Water 2
Black Water
Battery
R
G
G
G
Y
Содержание 2009 Pan America
Страница 17: ...A A A 11 Warranty and Service MAINTENANCE RECORD DATE DEALER SERVICE PERFORMED DATE DEALER SERVICE PERFORMED...
Страница 18: ...A A 12 Warranty and Service NOTES...
Страница 34: ...Towing B 16 B NOTES...
Страница 60: ...C 26 C Camping NOTES...
Страница 90: ...Interior E 14 E NOTES...
Страница 110: ...F 20 Plumbing F NOTES...