En-10
• STEP1 - STEP3
Butt the insulation
against the unit.
STEP 1
Unit
Slit
Press
fi
rmly
Press
fi
rmly
STEP 2
Slit
Press
fi
rmly
Roll the in-
sulation over
the joint.
Press
fi
rmly
STEP 3
Press
fi
rmly
Slit
• FINISH
Check that there is no gap between the unit and the drain hose insulation.
• When drain pump is used. (Ceiling concealed type only)
Do not cover the
panel window.
• When drain pump is not used. (Natural drainage)
Do not cover the
control box cover.
Note: Check for drainage
Pour about 1 liter of water from the position shown in the diagram or from
the air
fl
ow outlet to the dew tray. Check for any abnormalities such as
strange noises and whether the drain pump functions normally.
CAUTION
Make sure the drain water is properly drained.
6. ELECTRICAL WIRING
WARNING
Electrical work must be performed in accordance with this Manual by a person certi
fi
ed
under the national or regional regulations. Be sure to use a dedicated circuit for the
unit.
An insuf
fi
cient power supply circuit or improperly performed electrical work can cause
serious accidents such as electric shock or
fi
re.
Before starting work, check that power is not being supplied to the all units.
For wiring, use the prescribed type of cables, connect them securely, making sure that
there are no external forces of the cables applied to the terminal connections.
Improperly connected or secured cables can cause serious accidents such as
overheating the terminals, electric shock, or
fi
re.
Securely install the electrical box cover on the unit.
An improperly installed electrical box cover can cause serious accidents such as
electric shock or
fi
re through exposure to dust or water.
Install sleeves into any holes made in the walls for wiring. Otherwise, a short circuit
could result.
Use the included connection cables and power cables or ones specified by the
manufacturer. Improper connections, insuf
fi
cient insulation, or exceeding the allowable
current can cause electric shock or
fi
re.
Do not modify the power cables, use extension cables, or use any branches in the
wiring. Improper connections, insuf
fi
cient insulation, or exceeding the allowable current
can cause electric shock or
fi
re.
Match the terminal block numbers and connection cable colors with those of the
outdoor unit (or RB unit). Erroneous wiring may cause burning of the electric parts.
Securely connect the connection cables to the terminal board. In addition, secure the
cables with wiring holders. Improper connections, either in the wiring or at the ends of
the wiring, can cause a malfunction, electric shock, or
fi
re.
Always fasten the outside covering of the connection cable with the cable clamp. (If the
insulator is chafed, electric discharge may occur.)
Install an earth leakage breaker. In addition, install the earth leakage breaker so that
the entire AC main power supply is cut off at the same time. Otherwise, electric shock
or
fi
re could result.
Always connect the earth (ground) cable.
Improper earthing (grounding) work can cause electric shocks.
Install the remote controller cables so as not to be direct touched with your hand.
Perform wiring work in accordance with standards so that the air conditioner can be
operated safely and positively.
Connect the connection cable
fi
rmly to the terminal board. Imperfect installation may
cause a
fi
re.
If the supply cable is damaged, it must be replaced by the manufacturer, its service
agent or similarly quali
fi
ed persons in order to avoid a hazard.
CAUTION
Earth (Ground) the unit.
Do not connect the earth (ground) cable to a gas pipe, water pipe, lightning rod, or a
telephone earth (ground) cable.
Improper earthing (grounding) may cause electric shock.
Do not connect power supply cables to the transmission or remote controller terminals,
as this will damage the product.
Never bundle the power supply cable and transmission cable, remote controller cable
together.
Separate these cable by 50 mm or more.
Bundling these cables together will cause miss operation or breakdown.
When handling PCB, static electricity charged in the body may cause malfunction of
the PCB. Follow the cautions below:
• Establish an earth (ground) for the indoor and outdoor units and peripheral devices.
• Cut power (breaker) off.
• Touch metal part of the indoor unit for more than 10 seconds to discharge static
electricity charged in the body.
• Do not touch terminals of parts and patterns implemented on PCB.
9374342273-01_IM.indb Sec1:10
9374342273-01_IM.indb Sec1:10
7/12/2012 10:19:38 AM
7/12/2012 10:19:38 AM
Содержание ARXD07GALH
Страница 21: ...9374342273 01_IM indb Sec1 20 9374342273 01_IM indb Sec1 20 7 12 2012 10 19 48 AM 7 12 2012 10 19 48 AM...
Страница 41: ...9374342273 01_IM indb Sec1 20 9374342273 01_IM indb Sec1 20 7 12 2012 10 20 37 AM 7 12 2012 10 20 37 AM...
Страница 61: ...9374342273 01_IM indb Sec1 20 9374342273 01_IM indb Sec1 20 7 12 2012 10 21 25 AM 7 12 2012 10 21 25 AM...
Страница 81: ...9374342273 01_IM indb Sec1 20 9374342273 01_IM indb Sec1 20 7 12 2012 10 22 14 AM 7 12 2012 10 22 14 AM...
Страница 101: ...9374342273 01_IM indb Sec1 20 9374342273 01_IM indb Sec1 20 7 12 2012 10 23 02 AM 7 12 2012 10 23 02 AM...
Страница 121: ...9374342273 01_IM indb Sec1 20 9374342273 01_IM indb Sec1 20 7 12 2012 10 23 55 AM 7 12 2012 10 23 55 AM...
Страница 141: ...9374342273 01_IM indb Sec1 20 9374342273 01_IM indb Sec1 20 7 12 2012 10 24 44 AM 7 12 2012 10 24 44 AM...
Страница 161: ...9374342273 01_IM indb Sec1 20 9374342273 01_IM indb Sec1 20 7 12 2012 10 25 38 AM 7 12 2012 10 25 38 AM...