![Airspan AS4000 Скачать руководство пользователя страница 98](http://html.mh-extra.com/html/airspan/as4000/as4000_installation-and-commissioning-manual_2879131098.webp)
AS4000 Subscriber Terminal
Installation and Commissioning
DLP 009
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 4 of 18
Cabinet
M8 x 90mm Dyna-bolts (x4)
Wall
Figure 51. Enclosure (cut away) Fixed To Wall.
2.
Securing the Modular Enclosure to a wooden structure
1.
Using the Enclosure as a template, mark the first hole position.
2.
Drill a first hole pilot, 5mm diameter to a depth of 40mm (use a drilling depth
gauge),. Screw the M8 Coach Bolt provided through the enclosure into the
hole sufficient to position enclosure on the wall..
3.
Using a spirit level, adjust the position of the Modular Enclosure and mark the
remaining 3 holes. Remove the Enclosure.
4.
Drill the remaining pilot holes, 5mm diameter to a depth of 40mm, then fit the
Hex Head M8 Coach Bolts and washers provided through the enclosure into
the holes.
5.
Tighten all the bolts sufficient to ensure a firm fixing to the wall.