AS4000 Subscriber Terminal
Installation and Commissioning
DLP 009
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 13 of 18
9.
External cable connections to the Modular Enclosure
Sectioned View from top of Modular Enclosure showing base of unit
AC Cable
Inlet
AUX BATT Cable Inlet
(if required)
Inlet for Customer
Interface Cable(s)
Inlets for IF Drop
Cable(s)
MU interface wires
feed through end of
Krone connector.
MU1
MU2
MU3
MU4
+
-
Front
Figure 58. External cable connections to the Modular Enclosure
1.
Cabling to the Krone connectors in the Modular Enclosure is either four 4-pair
cables or one 20-pair cable. The cables enter the Modular Enclosure through
the base via a cable entry gland.
2.
Remove the Krone mounting panel
3.
Strip the cable and pass the wires through the hole in the connector mounting
panel to terminate on the top of each Krone block. Details of the cable
termination are shown in Figure 59 and Table 7 cables
4.
Run the RJ45 cables used to connect the Modular Units to the Krone blocks.
The cables from modular unit 1 pass through the cable eye at the left hand side
of the top Krone block.
The cables from modular unit 2 pass through the cable eye at the right hand
side of the top Krone block.
The cables from modular unit 3 pass through the cable eye at the left hand side
of the bottom Krone block.
The cables from modular unit 4 pass through the cable eye at the bottom right
hand side of the top Krone block.