Avoid the use of extension cables. If you use them, unroll them completely and
use cables of sufficient capacity. Use only cables with a diameter of at least 1,5
mm².
ATTENTION: while working the motor/air hose unit, reaches high
temperature. If working near this unit do not touch (risk of burning).
Limits for continuous operation
Curve no 1 indicates the length of
continuous running at varying
pressures, until the overload
protector switches off the motor (at
approx. 115 °C oil temperature
measured from 20 °C start point).
Example: 6 bar = 116 minutes.
Curve no 2 indicates the
recommendable proportion of
operation and standstill. Example: at
4 bar max. operation is 76% of the
time, corresponding to 46 minutes
operation/ 14 minutes standstill per
hour.
The curves represent average values at
230 V/50 Hz operation, with an outside
temperature = 20 °C.