5. FIRST USE
1.
After having removed the compressor from the packing, check that no parts
have been damaged during transport.
2.
The packing material has to be disposed of in compliance with the regulation
in force in the country where the compressor is being erected or recycled or
reused.
3.
Install the compressor on a flat surface, in a suitably sized room, well
ventilated and not wet, where the temperature is not likely to rise above 34
°C. If there is not enough air ventilation, install a suitably sized exhauster or
fan.
OIL MUST NEVER BE OVER THE MAX. OIL LEVEL.
To guarantee an optimal performance it is suggested to use Airpress
compressor oil (article no. 36398) with excellent resistance to alternate
thermal conditions and oxidation. DO NOT MIX DIFFERENT TYPES OF OIL.
Keep any oil remaining in the bottle for future topping up. Now insert the intake
filter on the pipe (or in the hole) with the pressure of your hand. After having
added the oil, never overturn or excessively tilt the compressor as this would
cause the oil run out. The power supply voltage must be the same as indicated
on the data label: 230 V/50 Hz and the socket must be 2 pole+ground type.
Fig. 1