6. OPERATING INSTRUCTIONS
Fig. 2
Fig. 3
If all the above indications have been followed, you can start the compressor as
follows:
- turn the pressure switch knob to position “0” (see fig. 1 and 2).
- insert the plug into the socket and start the compressor turning the pressure
switch knob to
position “1”.
The compressors working process is automatic. The pressure switch stops the
compressor when the pressure in the tank reaches the maximum value allowed
and starts it again when the pressure drops to the minimum value.
Adjust the outlet air pressure operating on the reducer-filter knob (see fig. 1 and
3):
a)
turning the knob clockwise the pressure will rise;
b)
turning the knob counter clockwise the pressure will decrease;
If the pressure switch does not work (overpressure), the safety valve will
automatically operate and open when the pressure exceeds the max. setted
value.
NEVER REMOVE OR REPAIR THIS VALVE.
WARNING!
The compressor must be connected to an outlet protected by a suitable
magneto-thermal switch.
The table below shows the absorption data of the compressor:
Model 36514
230 V/50 Hz
3,5A
750 W