Airplane Factory SLING 2
Pilot Operating Handbook
Page | 9-49
DC-POH-002-X-B-6
Revision : 2.6
SUPPLEMENTARY INFORMATION - ENGINE START
1. Master switch
- on.
2. EFIS back-up battery
- on, verify EFIS on and back-up battery
voltage.
3. Propeller switch (if applicable) - on.
4. Propeller (if applicable)
- AUTO.
5. Magneto / ignition switches (Lane A and B) - on (both).
6. EMS battery back-up switch
- on.
Once power (EMS battery back-up) is supplied the Lane A and Lane B warning
lights should illuminate for approximately 5 seconds and then extinguish. If
either or both lights flash or fails to illuminate it is indicative of a deficiency.
7. Fuel selector
- select emptiest tank (if not empty).
8. Throttle
- set to idle position.
9. Fuel pumps (both)
- on.
10. Propeller area
- clear of people and obstructions.
11. Starter
- activate (for maximum 10 seconds).
WARNING
Do not take the engine into
operation before having rectified
the cause of the deficiency.