WATER DRAINGE METHODS
This product has a self-evaporative system. The condensing water
will recycle to cool the condenser. This water-cooled mode can not
only improve cooling efficiency and decrease noise, but also save
energy for you.
* When in cooling mode, the water from the evaporator will flow into a inside
pan. When the water reaches the low level, the water pump will work until
the water is under the low level. When the water reaches the high level, the
compressor will stop working, and the water pump, lower fan motor and
upper fan motor will work on all the time.
* When in heating mode, the water pump won't work.
* When the water is full, the water full indicator will light and the compressor
will stop working. The buzzer will buzz 10 times every 5 minutes until the
water is below the high level or drained by hand. When the alarm stops and
after three-minutes restart delay, the unit will
work normally.
* Move the unit gently when the water is high. If
0
1
not , the water may spill from the inside of the unit.