* When the water in the cave is not enough for pumping, the pump will stop 

working. At the same time, the Water Injection indicator on the control panel 
will  illuminate  (

),  you  had  better  inject  some  water  into  the  water  draw 

carefully. In order to avoid the water flooding from the under pan, you should 
inject  water  no  more  than  1800ml  (three  cups).  This  operation  helps  save 
20%-30% energy for you.

MAINTENANCE 

Cleaning

Turn off the unit and pull the plug out of the socket before any cleaning. 

1.Clean the surface   

Clean the surface of the unit with a duster or a half-wet soft cloth. 
Do not use chemical solvent like benzene, alcohol, gasoline and etc, 
Or the surface may be damaged or even deformed. 

2. Clean the air filter 

If  the  air  filter  is  blocked  with  a  lot  of 
dust,  the  efficiency  will  reduce.  You’d 
better clean the filter every two weeks. 

1)  Pull out the air filter as Fig.14. 

2) Wash the air filter by immersing   
it  gently  into  warm(under  40

°

C  or  104

°

F)water  with  neutral  detergent.  Rinse 
the filter and dry it in a shaded place. 

3)  Push  the  air  filter  back  into  the 

original position. 

End of season 

1.Pull out the plug from the drain mouth and remove the water from the drain 
pan. You can remove the water entirely by slanting the unit back. 
Setting the fan mode, then press the Fan button for 5 seconds until the lower 
fan works. After that, operate the unit in fan mode for half a day until the pipe is 

1

1

 

Содержание APN212

Страница 1: ...AL APN212 PORTABLE AIR CONDITIONER Thank you for selecting super quality air conditioner Please be sure to read this manual carefully before using it Any question please contact the professional service for help ...

Страница 2: ...1 IMPORTANT SAFEGUARDS 2 FEATURES AND PARTS LIST 4 PANEL CONTROL 5 REMOTE CONTROL 6 OPERATION METHODS 7 INSTALLATION 8 WATER DRAINGE METHODS 10 MAINTENANCE 11 TROUBLE SHOOTING 13 INSTALLATION ACCESSORIES 14 APPENDIX 15 1 ...

Страница 3: ...rding to instructions When the power cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard Do not use your appliance with an extension cord unless it has been checked and tested by a qualified electrician or electrical supplier Return to the authorized service agent The air conditioning unit must always be stored and...

Страница 4: ...every 30 days Since the filters remove airborne particles more frequent cleaning maybe necessary depending on the indoor air quality Set the fan speed switch to high cool and the thermostat to the coolest position for the initial start up then set the Fan switch to Low cool and lower the thermostat to a comfortable setting Suggestions If room temperature is higher than 40 cooling function will not...

Страница 5: ...y saving and environment protect Low noise and strong wind Unique economic function Auto swing makes wind blow from left to right automatically Three minute restart delay to protect compressor Parts list 1 control panel 2 horizontal louver 3 vertical louver 4 air inlet grille 5 castor 6 exhaust duct 7 handle 8 air outlet grille 9 power cord and plug 10 water injection port 11 power and hook 12 air...

Страница 6: ...s button to select cool heat dry or fan mode heat mode only in YPC H models Econ press this button to a set energy saving mode only in heat and cool mode This set temperature is 27 in cool mode and 23 in heat mode The fan speed is low These data can t be changed The LED display will flash or accordingly Press again to cancel it when or is flashing Power press this button to turn on off the unit 2 ...

Страница 7: ...o choose Dry mode Fan Press this button to choose Fan mode Up Press Up or Down button to set temperature Down or adjust the time in Timer mode High Press this button to select high fan speed Med Press this button to select middle fan speed Low Press this button to select low fan speed Econ Press this button to a set energy saving mode only in Cool and Heat mode The set temperature is 27 in cool mo...

Страница 8: ... button once again during the flashing time Press the Timer set time end the unit will turn on automatically 1 Press Mode button or to choose Cool heat mode n o Press Up or Down butto r to set a proper room temperature F Th se The range is 18 30 64 86 e temperature will increase or decrea 1 or 1 F each time Press Speed button or to choose a proper fan speed Press Swing button or t d t the directio...

Страница 9: ...st terminal of the unit 2 Put the other end discharge to the nearest window Leave at least 50cm ally according to the place around it NOTE The leng 600mm to 1700mm adapters included We suggest using the minimum length of the air exhaust dust That can save energy for you This length has been designed es specifications of the air conditioner Do not use an extension or exchange of a different hose as...

Страница 10: ...4 Mounting illustrations 1 mounting in the wall 2 correct bending 3 wrong bending 9 ...

Страница 11: ...e low level When the water reaches the high level the compressor will stop working and the water pump lower fan motor and upper fan motor will work on all the time When in heating mode the water pump won t work When the water is full the water full indicator will light and the compressor will stop working The buzzer will buzz 10 times every 5 minutes until the water is below the high level or drai...

Страница 12: ...lvent like benzene alcohol gasoline and etc Or the surface may be damaged or even deformed 2 Clean the air filter If the air filter is blocked with a lot of dust the efficiency will reduce You d better clean the filter every two weeks 1 Pull out the air filter as Fig 14 2 Wash the air filter by immersing it gently into warm under 40 C or 104 F water with neutral detergent Rinse the filter and dry ...

Страница 13: ...ressed 2 Switch off the unit and disconnect the plug from the power supply 3 Tie the cable with sting 4 Remove the air exhaust duct and keep it carefully 5 Wrap the unit with the plastic bag and keep it in a dry place 6 Take the batteries out of the remote control and keep them well 12 ...

Страница 14: ...re Select suitable fan speed Too noisy and vibration It is the inner liquid refrigerant flowing inside Is it inclined It is normal Place it in a flat place The unit starts and stops frequently Is the voltage normal Is the exhaust tube fixed rightly or is it bended Have you added extra exhaust tube Turn off the unit if the voltage is abnormal Set the exhaust tube correctly Remove the extra tube Sto...

Страница 15: ...ESSORIES Description Flexible exhaust hose with adapters 2 set Window exhaust adapter flat mouth 1pc Adjustable window slider kit 2 set From 35 3 8 90cm up to 51 1 8 130cm Screw the length is 3 8 1pc Water cup 1pc 4 1 ...

Страница 16: ...APPENDIX Fuse Parameter Type FSD Voltage 250V Current 3 15A Disposal Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary 15 ...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Отзывы: