Use and maintenance manual Self-propelled aerial platforms Page 35
EV28 rear right levelling cylinder pad lowering.
CAUTION!
IT IS ABSOLUTELY FORBIDDEN TO ACTIVATE THE EMERGENCY CONTROLS OF THE LEVELLING
CYLINDERS WITH PLATFORM NOT IN REST POSITION. RISK OF MACHINE OVERTURN!
Once the emergency manoeuvres have been carried out, the knurled knobs must be set to their initial
position again in order to resume the operations (in normal position the knobs are completely
screwed).
5.7
Socket for electric tools connection and battery charger powering (electric models “E” only)
The platform is equipped with a socket (220-230V AC)
enabling the operator to connect the electric tools
necessary to carry out his operations and to power the
battery charger.
To activate the electric line (see picture aside)
introduce a cable into the socket (220-230V Ac. 50 Hz)
and set the earth-leakage circuit breaker switch, close
to the socket, to ON position. It is advisable to check
the earth-leakage circuit breaker by means of the
specially provided TEST button.
The plugs and sockets equipped on standard
machines comply with EEC standards and can
therefore be used in EU member countries.
On request the machine can be equipped with plugs
and sockets in compliance with local standards or with
particular needs.
Fig.12