Use and maintenance manual Self-propelled aerial platforms Page 23
5.1.4.6
Warning lights
Fig.6
5.1.4.6.1
Enabled station green warning light (O)
On with flashing light when the machine is turned on. If the platform control station has been selected and this warning light is
flashing, the controls are not enabled because the “dead-man” button (or “dead-man” pedal – Optional) was not pressed or
more than 2 seconds went by and no operation was performed (or “dead-man” pedal – Optional – was pressed for more than
10 seconds and no control was activated).
On steady with machine on and “dead-man” button pressed for less than 2 seconds (10 seconds for “dead-man” pedal –
Optional). With platform controls all controls are enabled (unless other types of warning show up – see next paragraphs).
5.1.4.6.2
Sliding platform position green warning light (P - only for machines with sliding platform)
This light is present on machines fitted with sliding platform (the whole platform can slide longitudinal).
When platform is not in central position, the warning light is OFF, and only platform extraction/retraction is possible.
When it is ON, the sliding platform is in central position, and the machine operation can be resumed (unless other warnings –
see next/previous paragraphs).
5.1.4.6.3
Flat battery warning light (Q – only electric and electro/diesel models)
Flashing when the battery charge is at 20% (only models "E" or "E/D" with current continuous electric pump). In this
condition, platform lifting is inhibited. It is necessary to recharge battery immediately.