background image

Power Cord

*Shown with optional mooring kit

Cord Strain 

Relief Attachment

Carabiner

Mooring Line

(Vinyl Coated Galvanized Wire)

PondSeries

 Fountain

Control 

Panel

Mooring Stake

Installing the PondSeries

 Fountain

A. System Components:

1.

  Fountain Pump with Quick Disconnect, Float Mount Ring and  

Classic Spray Pattern (installed)

2.

 Fountain Float

3. 

Power Cord

4. 

Control Panel

5. 

Crown & Trumpet Spray Pattern (interchangeable)

6. 

Trumpet Spray Pattern (interchangeable)

B. Prepping the PondSeries for Installation:

1)

  Ensure you have power close to your pond. If you don’t, we recommend to ALWAYS use a 

licensed electrician to properly run power down to the pond.

2) 

Mount the Control Panel in a fixed position next to the power source. (For control panel 
installation and wiring instructions for your fountain and light set, please see control panel 
manual for details.) 
 

a)

  If you are unable to perform installation of your control panel or light set please contact 

your Certified Airmax Service Technician and they can perform this installation for you.

3)

 

Choose Your Spray Pattern (Fig. 3)

 

 

a)

  The PondSeries automatically creates the classic pattern without a nozzle installed; 

however, the PondSeries includes two additional spray patterns  
(Trumpet and Crown & Trumpet).

 

b)

  To change a pattern, simply unscrew the nozzle nut, replace the pattern and reinstall the 

nozzle nut. We recommend removing the nozzle nut while displaying the classic pattern.

4) 

 

Assembling the Unit (Fig. 4)

 

a)

 Lay the float flat on the ground with Airmax logo facing up.

 

b)

 Place the fountain pump assembly into the center of the float. 

 

c)

  Lift the float straight up and ensure that the fountain pump lead power cord passes 

through the center hole. Gently lay the fountain to one side.

 

d)

 Securely attach the power cord to the fountain pump lead quick disconnect.

 

e)

 Attach the power cord strain relief to the loop underneath the float mount ring. (Fig. 2) 

 

f)

   Attach a mooring cable (not included) using two outside mounting locations on opposite 

sides of the fountain float (Fig. 2).

3. Setup & Installation

Classic

Trumpet

Crown & Trumpet

Fig. 3

Fig. 4

Unscrew Nozzle Nut to 
change Patterns

Mooring Kit Options:

#651052 – 

 150’ Mooring Kit

#651054 – 

 250’ Mooring Kit

#651055 – 

 500’ Mooring Kit

* Mooring Kit Not Included with Fountain

ENGLISH

• 2 stakes

• 2 carabiners

• 2 cable clamps

• 150’, 250’ or 500’ black vinyl  

coated galvanized cable  
(Mooring Line)

Recommended Mooring Kit

Fig. 1

Fig. 2

Strain Relief

Mooring Kit

4

Содержание PondSeries

Страница 1: ...ual 1 2 HP Fountain 115V 60Hz 652597 1 2 HP Fountain 230V 60Hz 652596 1 HP Fountain 230V 60Hz 652150 2 HP Fountain 230V 60Hz 652151 UNIT IDENTIFICATION Safe Simple Solutions Please Keep for Your Records Classic Trumpet Crown Trumpet Included Included ...

Страница 2: ...ain Ftn PondSeries 1 2 HP 1 HP 2 HP Floating Fountain OWNER S MANUAL FOR See in Action PondSeries Spray Patterns airmaxeco com pondseriesfountains SECTION TABLE OF CONTENTS PAGE 1 System Components 4 2 Safety 4 3 System Installation 5 4 Maintenance Winter Storage 5 5 Troubleshooting Fountain 5 6 Replacement Parts 6 8 7 Warranty 11 2 ...

Страница 3: ...ezing temperatures remove fountain and store inside If installing the fountain from a boat or raft ALWAYS wear a Coast Guard approved personal flotation device ALWAYS use a qualified electrician to install a power source Easy to Install Continuous Duty Water Cooled Motor Silicon Carbide SiC and Alumina Thrust Bearing Fully Sealed Motor UL Listed Composite and Stainless Steel Suction Screen Body Co...

Страница 4: ... the classic pattern without a nozzle installed however the PondSeries includes two additional spray patterns Trumpet and Crown Trumpet b To change a pattern simply unscrew the nozzle nut replace the pattern and reinstall the nozzle nut We recommend removing the nozzle nut while displaying the classic pattern 4 Assembling the Unit Fig 4 a Lay the float flat on the ground with Airmax logo facing up...

Страница 5: ...nt Reduce current load on circuit check other equipment Breaker tripped to GFCI 1 2 HP check GFCI breaker 1 2 HP check overload breaker IF NOZZLE HAS POOR QUALITY STREAMS ISSUE CORRECTION Intake plugged Clean intake Not enough water in reservoir Bring water level up to at least 36 at fountain Debris caught in nozzle hole Remove nozzle clean replace Water coming over the float Check fountain float ...

Страница 6: ...HP 7 653107 Thrust Bearing Assembly 8 651174 3 4 Stainless Coated Shaft 9 653108 Stainless Shaft Coupler Assembly 10 652158 Power Unit 115v 1 2 HP 652159 Power Unit 230v 1 2 HP 11 651861 Cooling Shroud Assembly 1 2 HP 12 653109 Intake Basket Assembly 1 2 HP 13 651500 Float 32 Blue w Airmax Logo Included Spray Patterns not pictured N A Classic Pattern 651887 Trumpet Pattern 651889 Crown Trumpet Pat...

Страница 7: ...not pictured N A Classic Pattern 651907 Trumpet Pattern 651909 Crown Trumpet Pattern For information on premium spray visit us online 651502 46 FLOAT ITEM NO PART NUMBER DESCRIPTION QTY 1 651502_46float_9Mar2016 Part 1 1 1HP POND SERIES FOUNTAIN B DO NOT SCALE DRAWING 652150 1HP FNT SHEET 5 OF 6 2 25 19 MM UNLESS OTHERWISE SPECIFIED SCALE 1 8 WEIGHT REV DWG NO C SIZE TITLE NAME DATE COMMENTS Q A M...

Страница 8: ...ed N A Classic Pattern 651897 Trumpet Pattern 651899 Crown Trumpet Pattern For information on premium spray visit us online 651502 46 FLOAT ITEM NO PART NUMBER DESCRIPTION QTY 1 651502_46float_9Mar2016 Part 1 1 1HP POND SERIES FOUNTAIN B DO NOT SCALE DRAWING 652150 1HP FNT SHEET 5 OF 6 2 25 19 MM UNLESS OTHERWISE SPECIFIED SCALE 1 8 WEIGHT REV DWG NO C SIZE TITLE NAME DATE COMMENTS Q A MFG APPR EN...

Страница 9: ...3 2 1 3 1 2 652159 POND SERIES POWER UNIT 1 2HP 115V 3 652156 Half HP Sand Slinger Washer Assembly 1 A B C D 4 3 652158 1 2 HP 115V Power Unit 1 652156 Half HP Sand Slinger Washer Asm 2 651878 Airmax 2 Wire Motor Lead 1 2 HP 115V Power Unit 652159 1 2 HP 230V Power Unit 1 652156 Half HP Sand Slinger Washer Asm 2 651878 Airmax 2 Wire Motor Lead 1 2 HP 230V Power Unit UNIT 651861 POND SERIES PVC COO...

Страница 10: ...M NO PART NUMBER DESCRIPTION QTY 1 651174 SS Shaft Nitrided Part 1 1 4 3 2 1 4 8 1 2 3 1 1 2 653108 3 4 SHAFT STAINLESS COUPLER ASSEMBLY 653107 PONDSERIES THRUST BEARING ASSEMBLY 653105 POND SERIES 1HP IMPELLER AND CLIP ASSEMBLY ART NUMBER DESCRIPTION QTY plined_coupler_SS 1 R _250 20_875 316 1 ITEM NO PART NUMBER DESCRIPTION QTY 1 651855 Thrust_bearing_holder29 NOV2015 Part 1 1 2 2 651649 silicon...

Страница 11: ...ies Intake 1 2 1 651620 POND SERIES LOWER SHROUD 653103 POND SERIES UPPER SHROUD WITH BEARING ASSEMBLY 652163 POND SERIES PUMP SCREW ASSEMBLY PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN TH DRAWING IS THE SOLE PROPERTY OF THE POND GUY INC ANY REPRODUCTION IN PART OR AS A WH WITHOUT THE WRITTEN PERMISSION O THE POND GUY INC IS PROHIBITED A B 4 3 2 3 1 653109 POND SERIES INTAKE BASKET A...

Страница 12: ...re may be a defect which may be covered under warranty it will be necessary to get a Return Material Authorization RMA from the dealer before shipment Freight collect shipments will not be accepted by the factory on warranties or repairs The product or part s must be returned freight prepaid to the factory as directed and in its original pack aging or in a container which will prevent damage Parts...

Страница 13: ... MI 48065 866 4 AIRMAX airmaxeco com Optional Single Arch Pattern Optional Double Arch and Geyser Pattern Optional Double Arch Pattern For Information on Optional Spray Patterns Visit Us Online at airmaxeco com pondseriesfountains 651190 V1 1 DIGITAL ...

Отзывы: