g)
Installing the Airmax LED Fountain Light Set (sold separately) (Fig. 5)
i)
To attach the light, clip the light into the mounting spot on the float and use the vertical tension
screw to secure the light into place. Continue until all lights are attached. Be mindful of the different
lengths of interconnect cord between lights. We recommend clipping up to an 8-light set into the
inside mounting positions.
ii)
After attaching the Airmax
LED Fountain Light Set to the float, connect the power cord to the light
kit quick disconnect. Adjust the lights to point to desired direction.
iii)
Attach the light set power cord strain relief on to one of the loops underneath the float mount ring.
Once lights are installed and
clipped into position, adjust
lights for desired direction.
Note
A. Maintenance
1)
Disconnect ALL power from the fountain and lights before attempting any maintenance.
2)
Periodically clean fountain intake screen of debris, algae and/or aquatic weeds.
3)
Periodically clean light set lens with a non-abrasive brush and cleaner.
B. Winter Removal & Storage
1)
Remove the fountain and lights from the pond before ice begins to form.
2)
This is the perfect time to clean or power wash any debris on the unit before storing.
3)
It is recommended to disconnect lights from fountain and store in an area above freezing temperatures.
C. Spring Installation Inspection
1)
Before re-installing the fountain and lights in the spring, check the condition of the power cord, quick disconnect connectors and replace any o-rings
that may be cracked or missing.
4. Maintenance & Winter Storage
3. Setup & Installation, cont.
ENGLISH
LED Light
PondSeries
Floating Fountain
Fig. 5
IF FOUNTAIN WILL NOT TURN ON
ISSUE
CORRECTION
GFCI Tripped
Reset GFCI
Power Cord Cut
Repair or replace power cord
Intake plugged
Clean intake
Timer not running
Check power to timer & battery back up
Not enough water in reservoir
Bring water level up to at least 36” at fountain
Fountain impeller stuck
Remove fountain, clean or replace impeller
Breaker tripped due to overcurrent
Reduce current load on circuit, check other equipment
Breaker tripped to GFCI
1/2 HP check GFCI & breaker
1 & 2 HP check overload & breaker
IF NOZZLE HAS POOR QUALITY STREAMS
ISSUE
CORRECTION
Intake plugged
Clean intake
Not enough water in reservoir
Bring water level up to at least 36” at fountain
Debris caught in nozzle hole
Remove nozzle, clean, replace
Water coming over the float
Check fountain float for water
IF FOUNTAIN STARTS AND STOPS
ISSUE
CORRECTION
Intake plugged
Clean intake
Not enough water in reservoir
Bring water level up to at least 36” at fountain
IF STREAMS RAISE AND LOWER
ISSUE
CORRECTION
Not enough water in reservoir
Bring water level up to at least 36” at fountain
Water coming over the float
Check fountain float for water, replace if any
IF FOUNTAIN IS HUMMING - RUNNING
ISSUE
CORRECTION
Normal running
Nothing
IF FOUNTAIN IS HUMMING - NOT RUNNING
ISSUE
CORRECTION
Intake plugged
Clean intake
Voltage not high enough for starting
Make sure voltage at receptacle is correct
Fountain impeller stuck
Remove fountain, clean replace impeller
5. Troubleshooting - Fountain
h)
Installing the PondSeries Fountain into your Pond or Lake
i)
Pick up the fountain by the float and place into the water.
Note: a minimum of 36” of water is required for proper operation.
ii)
Tie one side of the mooring rope to a stake and place the stake securely into the ground.
iii)
Take the other stake and mooring rope and walk around the pond, carefully pulling the fountain across the water. Once the fountain is in position, tie
the 2nd mooring rope to the 2nd stake and place securely into the ground.
iv)
Ensure both mooring ropes are snug to prevent the fountain from twisting and shifting during operation.
v)
To anchor the fountain using blocks, spread the blocks far apart so the mooring lines are snug and the fountain can not spin from the force of the
motor, which could cause the lines to get tangled.
* If your issue persists or is not covered in the troubleshooting guide above, please contact your Certified Airmax Service Technician
to perform any troubleshooting measures you are uncomfortable or unable to perform yourself. For fountain light set troubleshooting
measures please see the manual included with your light set.