5. Periodic Inspection/Maintenance
5
-
1
5.1 Important Items at Periodic Inspection and Maintenance or after
Maintenance
The manual shows proper interval for periodic inspection and maintenance under normally op-
erating conditions. Inspection and maintenance should be performed more often under ex-
tremely harsh conditions.
Hang a “Now Checking and under Maintenance” tag
Remove the starter key from the starter switch before starting
inspection, and hang up a “Now Checking and under Mainte-
nance” tag where it can be easily seen. The checker must keep
the key during checking and maintenance.
Remove the negative (–) side cable from the battery.
If the above procedure is neglected, and another person starts
operating the machine during check or maintenance, it could
cause serious injury.
Use tools appropriate for the inspection and maintenance. Any
makeshift or improper tools could cause unexpectedly injury by
their slippage.
SY001
Prevention of oil separator from catching fire
Be sure to perform oil change basically according to the speci-
fied interval. But if such oil is found much more contaminated
before the interval, change the oil even before the specified pe-
riod comes. In doing so, replace the oil completely and use our
recommended oil.
Be sure to perform following periodic inspection and mainte-
nance:
1. Check and change compressor oil
2. Change oil separator
Never mix the oil of different brands, or the mixed oil may dete-
riorate the oil quality.
Be sure to use recommended fuel, oil, grease, and antifreeze.
Do not disassemble or adjust engine, compressor or part(s) for which inspection or maintenance is not
referred to in this manual.
Use genuine parts for replacement.
Any breakdown, caused by using unapproved parts or by wrong handling, will be out of the scope of
“WARRANTY”.
Keep the electrical components away from water or steam.
Waste from machines contains harmful material. Do not dispose of such harmful fluids to the ground,
rivers, lakes or ponds, and sea. It contaminates the environment.
When draining waste fluid from machines, use leakproof containers to hold such fluids from machine.
Be sure to follow the designated regulations when disposing of oil, fuel, coolant, filters, battery and other
harmful things.
2
1
TR0423
Precautions for check and maintenance
Содержание PDSE900S-4B1
Страница 1: ......
Страница 14: ...1 Safety 1 11 The pasting position of safe warning label is as follows 5 4 3 6 6 8 7 11 A070196E 9 1 2 10 2 6...
Страница 60: ...8 Specifications 8 2 8 2 Outline drawing A040390 1 A070197...
Страница 61: ...9 Wiring Diagram 9 1 A090360E...
Страница 62: ...10 Piping Diagram 10 1 10 1 Compression air Compressor oil PDSE900S PDSF830S 4B1 A070141E 2...
Страница 63: ...10 Piping Diagram 10 2 PDSG750S 4B1 A070220E 2...
Страница 67: ......