IMPORTANT NOTICE
THE OPERATIONS INDICATED BELOW MUST BE FOLLOWED BY QUALIFIED PERSONNEL
EXCLUSIVELY, IN CONFORMITY WITH THE REGULATIONS IN FORCE.
THE MANUFACTURING FIRM REFUSES ALL RESPONSIBILITY FOR DAMAGES TO PEOPLE,
ANIMALS OR THINGS, RESULTING FROM THE FAILURE TO COMPLY WITH SUCH PROVISIONS.
INSTALLATION
Installing the top
The appliance is designed to be embedded into heat-resistant pieces of furniture. The walls of the pieces
of furniture must resist a temperature of 65°C besides the room one. The equipment must not be installed
near inflammable materials, such as curtains, cloths, etc.
Make a hole in the top of the piece of furniture, with the dimensions indicated in fig. 3 and in fig. 4, at a
distance of at least 50 mm from the appliance border to the adjacent walls. Any possible wall unit over the
cook-top must be placed at a distance of at least 760 mm from the top.
APPLIANCE
L
(mm)
P
(mm)
900x520 860
490
800x520
750
490
600x520
560
490
290X520 275
490
Fastening the top
Every cook-top is equipped with a special washer having an adhesive side.
- Remove the racks and burners from the top.
- Turn the appliance upside down and lay the adhesive washer S along the external border of the glass (fig.5).
- Introduce and place the cook-top in the hole made in the piece of furniture, then block it with the
screws of the fastening hooks C (fig.6).
Installation room
This appliance is not provided with a device for exhausting the products of combustion. Therefore, it
is necessary to discharge these smokes outside. The room where this appliance is installed must have a natural air inflow,
so as to ensure a regular gas combustion and room ventilation: the necessary air volume must not be lower than 20 m
3
.
Air must come from permanent openings made on the room walls that communicate with the outside. The section of these
openings shall correspond to at least 200 cm².
Gas connection
Make sure that the appliance is adjusted for the gas type available (see the label under the appliance). Follow the
instructions indicated in the chapter “gas transformations and adjustments” for the possible adaptation to different gases.
The appliance must be connected to the gas system by means of stiff metal pipes or flexible steel pipes having
continuous walls, in compliance with the regulations in force. Gas enters the appliance through a cylindrical threaded male
gas union (1/2”). The connection must not stress the gas ramp.
Once the installation is over, check the connection seal with a soapy solution.
Electric connection
The connection to the electric grid must be carried out by qualified personnel and in conformity with the
regulations in force. The voltage of the electric system must correspond to the value indicated in the label under
the appliance. Make sure that the electric system is provided with an effective ground connection in compliance
with the regulations and provisions of the law. Grounding is compulsory. If the appliance is not equipped with a
plug, apply a standardized plug to the power supply cable. It is possible to effect the connection to the electric grid
directly, by interposing an omni polar switch having a contact opening distance of at least 3 mm.