AirKing BFC90 Скачать руководство пользователя страница 3

www.airkinglimited.com

6727922 Rev. G 1/21

3 of 8

Standard Models

2. 

Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white), 
one ground (green or bare copper), and one hot (black lead connected to the switch). Secure 
the electrical wires to the housing with an approved electrical connector. Make sure you leave 
enough wiring in the box to make the connection to the fan’s receptacle.

3. 

Connect  the  White  wire  from  the  house  to  the  White  wire  from  the  fan’s  receptacle. 
Connect the Black wire from the wall switch to the Black wire from the fan’s receptacle. 
Connect  the  ground  wire  from  the  house  to  the  Green  wire  from  the  fan’s  receptacle 

(Figure 6)

. Use approved methods for all connections.

Humidity Sensing Models

3a.  For proper operation the humidity sensing fan will require a 3 way switch (not included). Run 

wiring between the fan and the switch location. Make sure you leave enough wiring in each 
box to make the connections. At the switch box connect the Black wire from the house to the 
common terminal of the switch. Connect the black wire from the fan to one of the switched 
terminals  on  the  switch. This  position  will  energize  the  automatic  mode  and  the  fan  will 
energize upon a rise in humidity. Connect the Yellow wire from the fan to the other switched 
terminal on the switch. This position will activate the Manual On feature and energize the fan. 
Properly connect the ground and neutral (if applicable) mount the switch and the cover.

3b.  Connect the white wire from the house to the white wire from the fan. Connect the ground 

wire from the house to the green wire from the fan housing 

(Figure 7)

. Use approved 

methods for all connections.

4. 

Carefully tuck wire back inside wire compartment and replace wire compartment cover 
securing with the screw that was removed earlier.

SECTION 6

Completing the Installation

1.  Use  a  sealant  appropriate  for  contact  with  the  building  materials  present  and  for  the 

temperature  requirements  of  the  installation  to  prevent  air  leakage  from  unconditioned 
spaces is recommended. If gaps between unit housing and ceiling are great, additional 
material (backing rod, ceiling material) may be required.

NOTE:

 This fan is rated for direct insulation contact (Type IC) and it is recommended that this fan 

be completely covered by insulation in order to reduce heat loss or gain to unconditioned space.

2. 

Plug the fan’s quick connect motor cord into the receptacle. This cord will only fit one way 
into the receptacle 

(Figure 8).

3. 

Install the grill by squeezing the two ends of the springs together and installing them up 
into the slots on the fan’s housing. Push the grill up into position 

(Figure 9).

4. 

Restore power and test your installation.

SECTION 7

Setting the Humidistat

This  fan  may  be  equipped  with  a  humidity  sensor  that  automatically  turns  the  fan  on  when 
humidity is above set point and off when humidity is at or below set point. If the fan is operating 
too  long  or  not  enough,  first  check  to  see  the  humidity  sensor  set  point.  In  cases  where  the 
ambient humidity level of the room rises higher than the preset level, the fan will turn on even if 
the room is not occupied. This helps prevent conditions that lead to mold growth.

CAUTION:

  MAKE  SURE  POWER  IS  SWITCHED  OFF  AT 

SERVICE PANEL BEFORE SERVICING THE UNIT.

1. 

To set the desired humidity level of the room, remove the grill and locate the dehumidistat 
dial located on the wire compartment cover. 

2. 

Set the dial to the relative humidity you want the fan to maintain usually between 50 & 
80%. Moist climates will require higher settings than dry climates. When the humidity 
level of the room is below this setting the fan will remain off. When the humidity level 
rises about this setting the fan will turn on and run until the humidity level falls below 
this setting. 

3. 

Reinstall the grill and restore power. 

SECTION 8

Use and Care

CAUTION:

  MAKE  SURE  POWER  IS  SWITCHED  OFF  AT 

SERVICE PANEL BEFORE SERVICING THE UNIT.

1. 

Cleaning the Grill:

 Remove grill and use a mild detergent, such as dishwashing liquid, 

and  dry  with  a  soft  cloth.  NEVER  USE ANY ABRASIVE  PADS  OR  SCOURING  POWDERS. 
Completely dry grill before reinstalling. Refer to instructions in 

Section 6

 

Completing the 

Installation

, to reinstall grill.

2. 

Cleaning the Fan Assembly:

 Wipe all parts with a dry cloth or gently vacuum the fan. 

NEVER IMMERSE ELECTRICAL PARTS IN WATER.

Figure 9

Figure 8

Figure 6

Supply from house

Black

Neutral (White)

Ground (Green or Bare)

Fan

Neutral (White)

Green

Black

By others

Figure 7

Supply from house

Black

Neutral (White)

Ground (Green or Bare)

Fan

Switch

(by others)

Black

Neutral (White)

Green

Yellow

By others

Содержание BFC90

Страница 1: ...xhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the...

Страница 2: ...housing in the previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 1 SECTION 4 Ducting NOTE 4 OR LARGER RIGID DUCT IS RECOMMENDED FOR BE...

Страница 3: ...insulation contact Type IC and it is recommended that this fan be completely covered by insulation in order to reduce heat loss or gain to unconditioned space 2 Plug the fan s quick connect motor cord...

Страница 4: ...be accepted CUSTOMER SERVICE Toll Free 800 465 7300 Our Customer Service team is available to assist you with product questions service center locations and replacement parts They can be reached Mond...

Страница 5: ...ombustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et les normes de s curit telles que celles publi es par la National Fire Protection Association N...

Страница 6: ...mit s des rails aux solives Figure 1 SECTION 4 Conduits REMARQUE UN CONDUIT PLUS RIGIDE DE 4 PO OU PLUS EST RECOMMANDE POUR UNE MEILLEURE PERFORMANCE ATTENTION TOUS LES CONDUITS DOIVENT TRE CONFORMES...

Страница 7: ...e inconditionn 2 Brancher le cordon raccordement rapide dans le r ceptacle Ce cordon ne s ajuste que d une seule fa on dans le r ceptacle Figure 8 3 Installer la grille en pressant ensemble les deux e...

Страница 8: ...pi ces de rechange Vous pouvez la rejoindre du lundi au vendredi de 8h 00 16h 00 HNE Veuillez avoir le num ro du mod le disponible ainsi quele genre et le style qui se trouvent sur l tiquette l int ri...

Отзывы: