All of the following information and instructions are only for 
authorized electricians.  

 

CHAPTER 6 

 

INSTALLATION 
 

 

6.0 

Scope of delivery / Mechanical Installation  

A  visual  inspection  upon  delivery  should  be  performed  including  a  check  to  ensure 
all components are present. Take the delivery unit out of the box immediately before 
installation in order to avoid possible damage and contamination during the transport 
as well as at the construction site.  

 

Scope of delivery: 
 
1. 

Facade

 

2. 

Terminal compartment 

cover 

incl. 4x fastening screws 

3. 

Control board

  

4. 

Plastic housing 

with impeller  

5. 

Guide vane

,

 

with limited 

mounting depth removable 

 

     

6. 

Backdraft shutter

removable  
7. 

Cable support sleeve 

x 2 

8. 

Mounting kit  

2x screws with dowels  
for a wall mounting   
9. 

Foam strips

     

 

6.1 

Preparation for wall mounting  

   

Safety instructions listed in Chapter 1.2 must be observed

!  

The  fan  is  supplied  as  a  standard  complete  unit,  which  is  delivered  ready  for 
connection. The installation and set-up of the fan should be performed only after final 
cleaning to avoid damage and contamination of the ventilation unit.   
After unpacking and before installation the following points must be checked: 
- if any transport damage is noticed, 
- broken or bent parts 
- free running of the impeller  
 

 

6.2 

Installation 

The  QuietAir  150  is  designed  for  direct  wall  mounting.  The  housing  must  not  be 
deformed  or  warped  during  the  installation.  Ensure  to  choose  a  flat  location  for 
mounting. Fans can be heavy and are sometimes unwieldy. Proper precautions must 
be  taken,  to  ensure  the  assembly  is  well  supported  and  stable  before  lifting  into 
position. Fans should be mounted only on sufficiently strong and stable nature using 
appropriate  fasteners.  Ensure  a  sufficient  additional  flow!  If  necessary,  read  an 
instruction from DIN 1946-6.      
 

 

 

1. Cable outlet in the wall 

- Position of the cable outlet in the dark area is variable (fig 4). 
- Clearance to the pipe centre depending on the cable outlet r = 83 mm (at a variable 
position from 0 up to 360

).  

- For an easy assembly, recommended to place outlet as shown (90

 rotatable). The 

optimal position is at 45

 when the cable outlet placed directly at the position of the 

cable support sleeve.   
- QuietAir 150 Pipe inner diameter = 

ᴓ 150 mm 

- Clearance to room corners: at least 130 mm from the pipe centre  
- During the wiring the side recess for the cable entry in housing (fig 7, Pos.1) must 
be broken out.  

   

 DANGER

 

Fig 3 

Содержание QT 150VS

Страница 1: ...nd Operating Instructions QuietAir 150mm Axial Fan MODEL QT 150VS Variable Speed Fan 50 260m3 hr With Adjustable Timer control Variable Speed with timer Low Energy Quiet Long Life Extra Safe 80000309...

Страница 2: ...ance Chapter 3 SPECIFICATIONS DIMENSIONS M1 150 0 10V 3 0 Specifications 3 1 Product lifetime 3 2 Accessories 3 3 Dimensions Chapter 4 FUNCTION 4 0 Function description Chapter 5 CLEANING DEINSTALLATI...

Страница 3: ...and accident prevention regulations must be observed All electrical work and commissioning must be carried out only by authorized and qualified electricians Maintenance and installation work must be c...

Страница 4: ...rly installed and used for its intended purpose product complies with the valid regulations and CE guidelines at the time of its production 1 5 Transport The fan is factory packed so that it is protec...

Страница 5: ...ectrical data this must be conformed to the local supply network On the test stand fan performance was complied with DIN EN ISO 5801 1 10 Noise data The noise data which relate to distances is valid u...

Страница 6: ...on inhibit activates the fan for 15 sec to protect the motor from rapid on off switching CHAPTER 3 SPECIFICATIONS DIMENSIONS M1 150 0 10 V 3 0 Specifications Impeller 137 Electrical supply NYM 0 2 x1...

Страница 7: ...be limited internally via internal potentiometer settings In delivery condition the full scope of the control range becomes available 2 Scaling Scaling can be set through the internal potentiometer i...

Страница 8: ...sible housing parts the external housing of the fan with a damp cloth Do not use any aggressive paint solvent cleaning agents High pressure cleaner or spray water is not permitted 5 1 Cover Dismantlin...

Страница 9: ...ter unpacking and before installation the following points must be checked if any transport damage is noticed broken or bent parts free running of the impeller 6 2 Installation The QuietAir 150 is des...

Страница 10: ...and wall plugs 3 Backdraft shutter and guide vane If required backdraft shutter scope of delivery can be installed behind the guide vane fig 6 During the housing installation the guide vane must be mo...

Страница 11: ...must take place in one wire Insertion of 2 wires in the grommet is not allowed In the wiring make sure that wires are placed not on the board but on the edge along the housing fig 9 10 For LiYY contr...

Страница 12: ...with supply cable through NYM O 4 1 5mm 2 Relays with low voltage consumers Connection combined with control line through LiYY 5 0 34mm 2 Wire transfer not over the board 1 Insert and tighten the ter...

Страница 13: ...an the following need to be checked regularly Appearance of dust or dirt in the housing on the motor and impeller Free running of the impeller Appearance of excessive vibration and noise In case of pr...

Страница 14: ...rminal N L Terminal N and L have to be connected to the 230V operating voltage Terminal 5 Terminal 1 activates the low stage Terminal 6 Terminal 2 activates the high stage Terminal 7 10 VDC Terminal 3...

Страница 15: ...rocessing work wherein the setpoint of 10 V the controller will reach the maximum value of 100 Thus in the delivery state complete bandwidth set is available for both setpoint input and speed control...

Страница 16: ...peed Note Minimum air operation and minimum rate of air can be achieved by electronic temperature sensors such as the ETR Type see accessories 4 Relay output An operating message will be displayed on...

Страница 17: ...5 Schematic overview for QuietAir QT150 VS Fig 17...

Страница 18: ...failure in Chapter 8 1 Bearing noise Vibrations see Chapter 8 1 Power consumption according to the specifications on the type plate see Chapter 8 1 8 1 Troubleshooting Safety instructions listed in C...

Страница 19: ...ion mechanical loading fatigue and or other effects that could not be directly discerned should be disposed in accordance with local and international laws and regulations The same applies to auxiliar...

Страница 20: ...le electrical supply 3 Has not been subjected to issue neglect or damage 4 Has not been modified or repaired by any person not authorised by Airflow Developments Ltd 5 Has been installed in accordance...

Отзывы: