Maintenance, care and servicing/ repair
AIRBOY | Version 1.07
13
8.3 Function test of the safety valve
Monthly check of the safety valve
Step 1: Open the safety valve by pulling the ring out-
wards (the pressure vessel must be under
pressure).
Step 2: Check the safety valve for proper function - Re-
gular starting of the safety valve is recommen-
ded per maintenance interval.
After the safety valve is triggered, the operator must turn
off the compressor and request control by the main-
tenance personnel.
8.4 Service
The company AIRCRAFT Kompressoren does not take
responsibility nor does it guarantee for damages and
failures resulting of non-observance of this operating
manual. For repairs only use faultless and suitable tools
and original spare parts or parts from series expressly
authorised by the company AIRCRAFT Kompressoren.
8.5 Information about the technical customer
service
Repairs to be performed under the warranty may only
be carried out by technicians authorised by us to do so.
Use only original spare parts.
For all your inquiries and orders, please always indicate
the TYPE DESIGNATION, the YEAR OF CONSTRUC-
TION, and the ITEM NUMBER of your compressor. You
can find all these indications on the type plate which is
fixed on the compressor.
8.6 Troubleshooting
DANGER!
Any servicing/maintenance work may only be car-
ried out by a specialized company or by duly trained
personnel. Any maintenance work on electrical
equipment may only be carried out by specialized
electrical staff or under the supervision and guid-
ance of an electrical specialist.
Malfunction
Solution
The compressor doesn’t reach the cut-out pressure.
Seals at the compressor or at the check valve leaking. Re-
place the seals.
The compressor switches off.
No malfunction, the storage tank is filled, maximum pres-
sure is reached.
The compressor stops and doesn’t start again.
The motor protection switch has triggered. Leave the
compressor switched off. Press the motor protection
switch after approximately 20 minutes and switch the
compressor on again. If the motor protection switch trig-
gers again after the restart, please contact the customer
service.
The motor is defective. Please contact the customer
service
The compressor only operates shortly until reaching the
cut-off pressure, and restarts a short time later.
Very much condensation in the pressure vessel. Drain
condensation.
The tank pressure drops.
Check all connections and tighten if necessary. If the pro-
blem persists, contact customer service.
The safety valve blows off.
1. Cut-off pressure at the pressure switch is set too high.
Reduce cut-off pressure at the pressure switch.
2. Safety valve defective. Replace safety valve.
The compressor doesn’t load end heats up excessively.
The cylinder head gasket or valve is damaged. Stop the
compressor immediately and contact Customer Service.