2-3 Performance of ACGC centrifugal gas unit heaters 

 

Centrifugal model. ACGC  
 

ACGC unit heaters are equipped with a centrifugal fan 
and are supplied as standard with an air case 
(assembly p. 9). 
 
They are intended for blowing or taking air from a 
sheath network.  
 
Mixture dampers and a filter can be incorporated on 
the air case. 

TYPES 

ACG20C 

ACG28C 

ACG35C 

ACG45C 

ACG55C 

ACG75C 

Calorific output  

kW 

21 

28 

35 

45 

55 

71 

Useable power  

kW 

19.5 

25.5 

31.5 

40.5 

50 

64.4 

Efficiency  

 % 

 > 91 

> 91 

> 91 

> 91 

> 91 

> 91 

Type of fan  

 

BD25/25 M6  BD28/28 M6  BD28/28 M6  BD33/33 M6  BD33/33 M6  BD33/33 M6 

Air flow at 15 °C  

Air flow at 50 °C 

m

3

/h 

1 700 

1 900 

2 050  

2 300 

2 800   

3 150 

3 900  

4 350 

4 400  

4 950 

5 400 

6 050 

Delta T° of air  

°C 

33.7 

36.6 

33.1 

30.5 

33.4 

35.1 

Pressure of available 

Pa 

120 

90 

135 

110 

135 

130 

Gas flow at 15°C 

                Natural  G20  

         Groningue  G25  

           Propane   G31 

20 mbar 

25 mbar 

37 mbar 

2.22 m

3

/ h  

2.46 m

3

/ h  

1.64 kg / h 

2.96 m

3

/ h  

3.29 m

3

/ h  

2.18 kg / h 

3.70 m

3

/ h  

4.11 m

3

/ h  

2.73 kg / h 

4.76 m

3

/ h  

5.28 m

3

/ h  

3.51 kg / h 

5.82 m

3

/ h  

6.43 m

3

/ h  

4.30 kg / h 

7.40 m

3

/ h  

8.22 m

3

/ h 

5.46 kg / h 

Smoke diameter  

mm 

80 / 125 

80 / 125 

80 / 125 

100 

130 

130 

Air input diameter  

mm 

100 

130 

130 

Supply voltage  
Electrical power  

VA 

860 

900 

920 

1250 

1350 

1700 

Weight  

kg 

99 

117 

125 

140 

165 

180 

Mono-phase 230 Volts / 50 Hz - IP42 

Motor electrical power   kW - Hp 

0.25 - 1/3 

0.37 - 1/2 

0.37 - 1/2 

0.75 - 1 

0.75 - 1 

1.1 - 1.5 

Motor rotation speed  

Rpm  

720 

680 

850 

750 

860 

980 

 

Motor coupling  

Speed 

— 

MV 

GV 

PV 

MV 

— 

Flow/pressure curve  

N° 

10 

ACG95C 

92 

84 

> 91 

BD33/33 M6 

2×(0.75-1) 

750 

PV 

7 600 

8 500 

29.1 

130 

10.00 m

3

/ h  

11.1 m

3

/ h  

7.4 kg / h 

130 

130 

2 400 

260 

Preparation for assembly : 

Disassemble the side panels (1) and (2) of 

the fan case  

 

Assembly of A and B : 

Assemble the fan case A on the thermal 

case B, using the 4 BTR M8 (3) screws 

provided.  

Caution : 

Position the fan supply electrical 

connector (5) at the supply cable end (7), 

               See photo (I) above.

 

Electrical connection : 

Connect the fan connector (5)  with the 

thermal module connector (6), see photo (II) 

above. 

 

Reinstall the side panels (1) and (2) using 
the hardware supplied. 

 

A – Fan case  
B – Thermal case 

 

Assembly of the fan case for ACGC

 

II 

Содержание ACGC 20

Страница 1: ...1 DTC AT 13 135 FR GAZ FIRED AIR HEATERS TECHNICAL NOTICE AND INSTRUCTIONS FOR MONTAGE ACGH 16 20 28 35 45 55 75 95 ACGC 20 28 35 45 55 75 95 ACGV 26 28 36 45 55 75 95 1312BO3933...

Страница 2: ...16 20 26 28 35 36 45 55 10 3 2 Rotation console for IPN adjustable for ACGH 16 20 26 28 35 36 45 55 10 3 3 Adjustable wall mounted console for ACGH75 95 11 3 4 Adjustable wall mounted console for ACGC...

Страница 3: ...ich accompany the product at its shipment can be considered as contractual keep the instructions carefully near the device 1 1 Description of the device Operation The ACG gas unit heater is a generato...

Страница 4: ...on which is unsuitable or not in conformity with current standards Only defects in manufacture or raw materials are concerned The guarantee is limited to the replacement of parts which are found to be...

Страница 5: ...er mm 80 125 80 125 80 125 80 125 80 125 80 125 100 130 130 130 Air inlet mm 100 130 130 130 Supply voltage Electrical power VA 290 300 310 310 320 320 350 500 580 750 Weight kg 54 81 82 82 85 85 105...

Страница 6: ...V Calorific output kW 26 36 45 55 71 92 Usable power kW 23 5 32 5 40 5 50 64 4 84 Efficiency 91 91 91 91 91 91 No of fans 1 1 1 1 1 2 Rotation speed Rpm 900 900 900 1400 1400 900 Air flow at 15 C Air...

Страница 7: ...128 490 217 677 100 100 1 2 The ACGV models are retained at their upper part by four tightened M8 nuts Blowing is vertical towards the ground and the installation height must not be lower or higher th...

Страница 8: ...4 76 m3 h 5 28 m3 h 3 51 kg h 5 82 m3 h 6 43 m3 h 4 30 kg h 7 40 m3 h 8 22 m3 h 5 46 kg h Smoke diameter mm 80 125 80 125 80 125 100 130 130 Air input diameter mm 100 130 130 Supply voltage Electrical...

Страница 9: ...w pressure curves with filter consult us for this application Maximum dimension of the ACGC models and optional accessories A A1 A3 B B1 H L L1 L2 F Air AT 20 1040 750 780 480 440 460 356 381 310 80 1...

Страница 10: ...ke sure of the strength of the bracket C ACG16 H ACG20H ACG26H ACG28H ACG35H ACG36H ACG45H ACG55H Connection B22 C32 B22 C32 B22 C32 B22 C32 B22 C32 B22 C32 B22 C32 B22 C32 Dim A mm 110 160 162 160 18...

Страница 11: ...CG35C ACG45C ACG55C ACG75C Connection B22 C32 B22 C32 B22 C32 B22 C32 B22 C32 B22 C32 Dim A mm 115 125 115 125 115 125 125 190 135 205 135 205 Dim B mm 205 205 230 245 295 410 Dim C mm 585 585 585 585...

Страница 12: ...cs of the gas heaters ACGH ACGC 4 ELECTRICAL WIRING 4 2 Electrical schematics of centrifugal gas air heaters ACG75 Phase brown Neutral blue Earth green yellow Pilot black Phase brown Neutral blue Eart...

Страница 13: ...Inspection box MVE Smoke extractor PA Burner air pressure switch SI Ionisation sensor EA Ignition electrode MOD Gas modulating valve 2 speed option EVG Gas solenoid valve TI Isolation transformer Und...

Страница 14: ...orced ventilation and remote resetting Several models of thermostat 4 are available The use of these thermostats will provide you with supplementary functions such as remote resetting and forced venti...

Страница 15: ...EG112 Individual controller without thermostat Ambient thermostat with on off fan switch and remote resetting Clock programmable ACG gas unit heaters are equipped as standard with a receiver which ena...

Страница 16: ...h of 250 500 1000 mm 6 Concentric length of 500 1000 mm 7 Sealed elbow at 45 or 90 8 Concentric elbow at 45 or 90 9 Flat flashing 10 Tilted flashing with lead strip 4 6 9 10 5 3 Connecting to the unit...

Страница 17: ...n air inlet and smoke evacuation are vertical through the roof to the outside of the building The connection is concentric in diameter 80 125 and is connected directly onto the unit heater The KC3280...

Страница 18: ...total length of the circuit must not exceed 8 metres taking into account that an elbow of 90 or 45 corresponds to a length of 1 metre A double wall conduit must be provided if the part outside the bui...

Страница 19: ...hanging the seals Item 4 and making sure concerning sealing The injectors must be installed dry 5 Reassemble the ramp and connect the gas line to the gas valve replacing the seal make sure during asse...

Страница 20: ...lator pressure Gas ramp injectors Extractor washer Low speed High speed Low speed High speed Low speed High speed ACG16 6 mbar 9 mbar 4 x AL 1 90 40 7 mbar 12 mbar 4 x AL 1 90 40 13 mbar 25 mbar 4 x A...

Страница 21: ...delivered with the device Tighten the union onto the network before connecting it to the unit heater Check that the gas supply circuit is correctly sealed upto the gas solenoid valve see schematic 8...

Страница 22: ...22 ATE024 ATE022 ATE025 13 Inspectioni and safety box ATE318 ATE318 ATE318 ATE318 ATE318 ATE318 ATE318 14 Burner regulation airstat 65 C ATE146 ATE146 ATE146 ATE146 ATE146 ATE146 ATE146 15 Fan airstat...

Страница 23: ...and clean them Injectors Clean the gas injectors Ionisation sensor and electrodes Check their condition change them if necessary Gas filter Disassemble the dirty cartridge and clean it with compresse...

Страница 24: ...ing Check the pressure The device goes into safety position during operation red light comes on Gas supply interrupted Reset by pressing the red push button on the control box Cold air when starting I...

Отзывы: