Page 85
71.40.00 Attach Fittings
The engine set-up is standard as per Rotax specifications, however there are some simply attached
fittings that are extra or necessary.
The SkyDAT data collection
The SkyDAT box is mounted to the mast block using a small mounting plate.
Radiator
The radiator is attached to the engine mount assembly via four rubber mounts. These rubber mounts
should be checked for any wear of the rubber and replaced as necessary.
Coolant Overflow
The coolant overflow bottle is attached to the engine mount using Velcro straps.
71.50.00 Electrical Harness
The electrical harness for the system is routed between the fuel tank and the engine, it incorporates the
engines system, including the start system, and the SkyDAT wiring loom. The wiring loom is easy to
find and access and should be self explanatory when inspected in conjunction with the Rotax manual,
The Trike Electrical schematic and the SkyDAT manual.
71.70.00 Engine Drains
In addition to the fuel tank draincock there are two engine drains.
The Gear Box Oil sump has a drain which is on the under side of the gear box.
The coolant overflow goes down near the mast and exits at the base of the engine mount in the same
position as the fuel tank overflow and breather tube.