 3.2  Product overview

1.

Cistern 

- A place to store water for evaporation and air 

cleaning.

2.

Disk

 - The water in the cistern is pumped up and a 

water film is formed on the surface with the water 
being evaporated and the minute dirt being eliminated.

3.

Body  (Main Frame)

 - The fan and motor that control 

the air flow is located here and clean air is supplied 
through the exit duct in the left and right side.

4.

Operating panel

 - It contains power button and 

operation mode selection button. Also, it contains the 
window which shows the operational status.

5.

Disinfectant device (BSS: Bio Silver Stone)

 - Placed 

in the floor of the cistern, it prevents and 
contamination.
※Although the life cycle of the disinfectant may vary, 
it should accommodate an operation period of 24 hours
a day for about 12 month. (For repurchase of the part, 
please consult the customer service center.)

6.

Power cord

 - Supplies Electricity to the Product.

7.

Upper cover

 - The upper side is dried and the 

contaminated air is taken in.

8.

Water level gauge

 - It is possible to see the water level

from outside.

9.

Pre-filter

 - It eliminates the dust of intake air first.

1. Water sensor - 

Caution: Please wipe the sensor every 
week. Water level may not be detected if 
it is contamined.

2. Water level

It is marked on each side of inner part of 
the water tank. Fill water not to exceed the
line.

3.

Disinfectant device (fixed part) 

-  It is located inside of the tank at the bottom right.

4.

Disc fixing part 

-  Fix it properly on the front and back side of the disc.

1.

Cap –

 The disk is easily separated if you 

turn it by using a coin in case of disk 
washing.

2.

Warning: 

The side with sticker attached 

is the front. The product will not operate if
the front and back of the tank are changed.

 3.3  Operation preparation

Page 8 of 17

Содержание AIRWASHER

Страница 1: ...rate it and to get advice in the event of faults Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects...

Страница 2: ...al friendly material BSS BSS Bio Silver Stone non chemical material kills and eliminates various kinds of germs and viruses inside the water tank Germ killing by more than 99 99 3 Very easy for cleani...

Страница 3: ...rseas uses when the voltage is different it many fail to work or fire may ensue Warning Please avoid exposure to direct light places of high heat or near heaters Change of color or form may occur in t...

Страница 4: ...ution Don t use it close to other electric housing appliance Keep at least 30cm of distance from them to minimize harmful effect Warning Do not sit or step on the product The product may be broken and...

Страница 5: ...rm water which is under 40 Warning Do not forcefully enter sticks or fingers into the intake or the exhaust or attempt to independently remodel or separate the product May lead to product malfunction...

Страница 6: ...purpose without consultation The disinfectant material may affect the respiratory organs Warning Do not handle with force the disinfectant device BSS surface The content may damage Do not separate or...

Страница 7: ...r cord is plugged in the socket Caution Clean or supply water after plugging out from the power 3 Correct Operation 3 1 Installation After moving to place of installation read the Safety Advices first...

Страница 8: ...bout 12 month For repurchase of the part please consult the customer service center 6 Power cord Supplies Electricity to the Product 7 Upper cover The upper side is dried and the contaminated air is t...

Страница 9: ...se insert the connector to the product first and then insert the plug to the wall socket When disconnecting the power cord please pull out the plug from the wall socket first and then separate the con...

Страница 10: ...of the LCD window will be reduced to half when one minute would have passed after the last operation was selected 3 5 Resupplying of water For water resupplying just fill it with insufficient amount 1...

Страница 11: ...duct might malfunction or you might get electrocuted It should be cleaning by a tightly squeezed wet towel for its interior and exterior Stop operations and remove the electrical line power cord from...

Страница 12: ...is a danger of dropping it The product can smell if it has lot of dust having not cleaned for a while Although foreign materials on the cistern and the discs would not make them look good they do not...

Страница 13: ...nd does not move If you use the Easy Kit Brush you can tighten the cap easily 3 9 Cleaning pre filter once a month Please clean as following if the air suction fan and its area are very dirty Caution...

Страница 14: ...er part cover by pushing slightly in the four places until you hear the sound click 3 11 Cleaning Plasma ion generator The air blowing part would be cleaned periodically once in every year If the prod...

Страница 15: ...mode the fan stops if the room humidity exceeds 60 6 Haven t you pressed stop button Please press the power button on the left Disks do not turn 1 For the upper part of the main frame and the lower p...

Страница 16: ...ted so there is no need for any worry But please be sure to wash surely one time a week The color of the disinfectant device has changed This is due to the silver ionization of oxygen in the disinfect...

Страница 17: ...ust not be disposed in the normal unsorted municipal waste stream Old appliances must be collected separately in order to optimize the recovery and recycling of the materials they contain and reduce t...

Отзывы: