1.  Make sure the air cleaner is securely 

fastened to the true ceiling. 

 

2.  Replace the power module (X-11Q only) and 

reconnect the electronic plugs. 

 

3.  Check to make sure the electronic cells are 

oriented for correct airflow--arrows on side 
of cell should point up. The contact board 
on the cell should align with the contact 
board on the power module. 

 

4.  Make sure the intake grille opens easily and 

the electronic cells and the prefilter are 
secure in the unit. 

5.  Turn the electrical power back on. 

 

6.  Make sure the fan runs on all three-speed 

settings. The system light should be on 
when the fan is running. 

 

7.  Press the test button. An audible snap 

indicates the collection section of the cell is 
functioning. 

 

8.  Opening the intake grille stops the fan and 

turns out the system light. 

 

9.  Clean up surfaces of the air cleaner and the 

installation area. 

 

NOTE: If the air cleaner does not appear to work right, refer to the Electrical Troubleshooting section.

 

 

 

 

SAFETY INTERLOCK SYSTEM - 

In order for all 

air cleaner functions to receive operating power, 
the grille must be securely in position.  This 
actuates the safety interlock switch. The air 
cleaner will not function without the grille in place. 

 

FAN SWITCH 

- Your electronic air cleaner has an 

Off-Low-Med-Hi switch.  The electronic 
collection system and built-in fan are designed to 
run simultaneously. Turn off the air cleaner 
before opening the access door to remove the 
electronic cells for cleaning. 

SYSTEM LIGHT 

- Your electronic air cleaner is 

equipped to tell you simply and quickly that it is 
working properly.  The amber system light  tells  
you at a glance the status of the power supply. 
The system light should be on when the unit is on. 

 

TEST BUTTON 

- Pushing the white button labeled 

“push to test” generates a snapping noise that 
indicates proper function of the collector cells. 

OPERATING INSTRUCTIONS

 

CHECKOUT

 

Page 9

S M O K E M A S T E R   C - 1 2   O W N E R ' S   M A N U A L 

Pure n Natural Systems, Inc.  |  purennatural.com  |  1-800-237-9199

Содержание SMOKEMASTER C-12

Страница 1: ...ior written consent of Air Quality Engineering Inc All statements technical information and recommendations in this manual or related documents are believed reliable but the accuracy and completeness thereof arenot guaranteed or warranted and they are not intended to be nor should they be understood to be representation or warranties concerning the products described Specifications are subject to ...

Страница 2: ...aden air successively through the prefilter the cell ionizing section and the cell collector section The ionizing section imparts an electrical charge to the individual particles that are then drawn by electrostatic forces to the oppositely charged collector plates Cleaned air is then discharged back into the room The electronic cells must be washed periodically to maintain efficient performance F...

Страница 3: ...f no less than 15 cubic feet of air per minute per person Additional ventilation may be required for toxic contaminants In any event the air cleaner must be used only in areas that are ventilated for human occupancy in order to dissipate any incidental generation of ozone DIMENSIONS 25 x 25 x 11 635 mm x 635 mm x 279 5 mm WEIGHT 79 Lbs 36 Kg shipping 69 Lbs 31 Kg installed including electronic cel...

Страница 4: ...or Allows easy access to components for periodic cell and prefilter cleaning Safety interlock discharges allpower when the door is opened Built in test button assures collector performance Mounting Mounts on wall brackets or with steel suspension rods For mounting directly to a joist ceiling lag screws areavailable Plug Plugs into any regular 120 or 240 volt grounded outlet depending on voltageord...

Страница 5: ... 07071 07089 5 Door Interlock Switch 10106 10106 6 Motor Kit 05299 05014 7 Fan 37009 37009 8 Power Cord 42078 42027 9 Control Switch 10110 10110 10 Indicator Light 10097 10097 11 Intake Grille Light 20025 20025 Intake Grille Black 20026 20026 NP Ionizer Wire 38004 18 38004 18 C 12 Parts List Page 5 S M O K E M A S T E R C 1 2 O W N E R S M A N U A L Pure n Natural Systems Inc purennatural com 1 80...

Страница 6: ...ck the existing air circulation in the room The C 12 should be installed so that it aids the circulation already established When airflow patterns are not immediately apparent observe the smoke from a cigarette in various locations within the room Figure 6 C 12 Installation Dimensions Ceiling Mounting The C 12 is mounted by suspending it from the ceiling The mounting holes in holes in the C 12 are...

Страница 7: ...also be mounted using 3 8 in 10 mm diameter threaded steel rods available in many hardware stores Four steel rods will be required WALL MOUNTING Two wall mounting brackets are used to support the C 12 They are included in an accessory package along with a blank plate to block off the outlet louvers on the side of the air cleaner which will be against the wall The two brackets must be mounted on th...

Страница 8: ... C 12 junction box cover Figure 12 2 Disconnect and discard the power cord the solderless connectors and strain relief Plug the power cord hole with the plug provided 3 Run conduit from the power supply to the junction box through the appropriate knockout Fish wires to junction box 4 Connect lead wires with solderless connectors including ground green wires Proper grounding of this device is manda...

Страница 9: ...to work right refer to the Electrical Troubleshooting section SAFETY INTERLOCK SYSTEM In order for all air cleaner functions to receive operating power the grille must be securely in position This actuates the safety interlock switch The air cleaner will not function without the grille inplace FAN SWITCH Your electronic air cleaner has an Off Low Med Hi switch The electronic collection system and ...

Страница 10: ...llow better release of contaminant when washing 7 Check the electronic cells for broken wiresand bent collector plates The cells may be installed in the air cleaner and energized The indicator light may remain off during the normal two hour drying time However if annoying arcing occurs during this period the cell may be removed to dry 8 CELL CLEANER IS REUSABLE SAVE FOR REPEATED USE Replace cleani...

Страница 11: ...power at the fuse or circuit breaker 2 Open the intake grille Remove the cells to provide access to the motor 3 Remove the fan blade from the motor 4 Disconnect the fan motor leads at the plastic connector near the fan motor C 12 POWER SUPPLY REPLACEMENT PROCEDURE 1 Disconnect power from the unit 2 Disconnect quick connect terminals from power supply Unplug power supply wire harness 3 Remove 4 scr...

Страница 12: ... cleaner to function effectively without arcing Remove all parts of the broken wire If necessary the cell may be temporarily used with one wire missing 1 Use care to avoid damage to the spring connector or other parts of the cell during the installation 2 Hook one end of the ionizing wire over the spring connector at one end of the cell 3 Hold the opposite eyelet with a needle nose pliers and stre...

Страница 13: ...N ON LAMP OFF 1 If the fan is on and the light is out the problem is with the electronic cell or high voltage power supply 2 To determine which component is faulty Remove the electronic cell and operate the air cleaner If the light does not come on then the high voltage power supply will have to be replaced 3 If the indicator light does come one the problem is with the electronic cell Check the ce...

Страница 14: ...r serviced by anyone other than an authorized service technician using genuine AQE parts 4 UNAUTHORIZED PARTS A showing by the original purchaser that the Product has had only genuine Air Quality Engineering Inc parts and filters used in its operation and maintenance 5 SERIAL NUMBER INTACT A showing by the original purchaser that the Serial Number has notbeen altered or removed 6 MISUSE A showing ...

Отзывы: