background image

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. 

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions

should always be followed to reduce the risk of fire,

electric shock and injury to person, including the following:

SAVE THESE INSTRUCTIONS

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND 

INJURY TO PERSON, OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer.If you have 

questions, contact the manufacturer.

b)  Before servicing or cleaning the unit, switch power off at service 

panel and lock the service disconnecting means to prevent power 

from being switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND 

INJURY TO PERSON, OBSERVE THE FOLLOWING: 

a)  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-related construction.

b)  Sufficient air is needed for proper combustion and exhausting of gases 

through the flue (chimney) of fuel burning equipment to prevent back 

drafting. Follow the heating equipment manufacturer’s guideline and 

safety standards such as those published by the National Fire Protection 

Association (NFPA) and the American Society for Heating, Refrigeration, 

and Air Conditioning Engineers (ASHRAE), and the local code 

authorities.

c)  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

CAUTION:

 

FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO 

EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.

d)  Ducted fans must always be vented to the outdoors.
e)  This unit must be grounded.
f)  To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

g)  Read all instructions before installing or using exhaust fan.

WARNING:

 DO NOT INSTALL OVER A TUB OR MOUNT IN A SHOWER 

STALL ENCLOSURE.

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT 

USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.

WARNING:

 DO NOT USE IN KITCHENS.

www.airkinglimited.com

210572063 Rev. C 1-13

1 of 12

Exhaust Fan with Light

Models:  DRLC701, DRLC702, 
 

DRLC703, DRLC709

Содержание DRLC701

Страница 1: ...tion work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper combu...

Страница 2: ...g so that it will be flush with the finished ceiling Secure the ends of the rails with screws or nails not included to the joists and slide the housing into the final position Figure 3 1b Mounting Tab...

Страница 3: ...with an approved electrical connector Make sure you leave enough wiring in the box to make the connection to the fan s receptacle 2a From where you have access to inside the fan s junction box connec...

Страница 4: ...ecuring in place with the lens knob removed in step 3 Figure 14 8 Restore power and test your installation SECTION 7 Use and Care CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTI...

Страница 5: ...Y INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACEMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO...

Страница 6: ...4 1 Goose Neck Wire Cover 5S1201004 5 1 Receptacle 5S1999001 6 1 Polarized Connector 2P 5S1201012 Qty Description Replacement Part 7 1 Motor with Impeller 5S1201031 8 1 Scroll 5S1201006 9 1 Light Asse...

Страница 7: ...ersonne s qualifi e s en conformit avec tous les codes et normes applicables incluant la construction relative aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et l v...

Страница 8: ...live En utilisant le guide sur le ch ssis du ventilateur aligner le ch ssis pour qu il soit effleurement avec le plafond fini Fixer les extr mit s des traverses avec des clous ou des vis non comprises...

Страница 9: ...iques au ch ssis avec un connecteur lectrique approuv Vous assurer de laisser suffisamment de c ble dans la bo te pour faire le raccordement au r ceptacle du ventilateur 2a Par l o vous avez acc s l i...

Страница 10: ...la grille en d vissant le bouton au haut des lentilles Figure 11 Remplacer l ampoule les ampoules avec une des ampoule s incandescente s culot moyen de type A19 de 60 watts au maximum 4 R installer e...

Страница 11: ...CTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUSIBLES DISJONCTEURS OU R CEPTACLES DE MAISON MALGR N IMPORTE QUOI L EFFET CONTRAIRE DANS AUCUN CAS LA RESPONSABILIT D AIR...

Страница 12: ...ol de cygne 5S1201004 5 1 R ceptacle 5S1999001 6 1 Connecteur 2P Polaris 5S1201012 DIAGRAMME DES PI CES DE REMPLACEMENT de pi ce Qte Description de remplacement 7 1 Moteur avec h lice 5S1201031 8 1 Vo...

Отзывы: