Air King APDQ Series Скачать руководство пользователя страница 6

www.airkinglimited.com

5085462 New 2-12

6 of 12

  #    Qty.  Description 

Replacement Part # 

  1    1 

Louver Plate 

5S1429006 

  2    1 

Damper Frame 

5S1999013 

  3   1  Damper 

5S1999014 

  4   1  Blower 

5S2144001 

  5    1 

Bottom Cover 

5S1111032 

  6    2 

Grease Filter 

5S1111033 

  7    1 

Front Panel 

5S1145032 

  8    1 

Lamp Bracket 

5S1136099 

  9    1 

Fan Switch 

5S1418006 

  10    1 

Light Switch 

5S1136069 

  11    1 

Name Plate 

5S1421006 

REPLACEMENT PARTS DIAGRAM

  #    Qty.  Description 

Replacement Part # 

  12    2 

Lamp Holder 

5S1145051 

  13    1 

Fuse Outlet Harness 

5S1145052 

  14    1 

Lamp Holder Connector 

5S1145053 

  15    1 

Fuse Holder 

5S1199025 

  16   1  Fuse 

5S1111054 

  17    1 

Light Harness 

5S1145055 

  18    1 

Cap Harness 

5S1145056 

  19    1 

Crimp Nut 

5S1145057 

  20    1 

Main Harness 

5S1137049 

  21    1 

Wire Cover 

5S1145061 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

Содержание APDQ Series

Страница 1: ...ng do not damage electrical wiring and other hidden utilities CAUTION TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALL...

Страница 2: ...hood www airkinglimited com 5085462 New 2 12 2 of 12 SECTION 3 Prepare the Hood for Installation 1 Choose the type of ducting you will require This model is equipped to vent either Vertically or Horiz...

Страница 3: ...and the loose Black wire from the range hood to the Black wire of the supply Connect the ground wire green or bare from the supply to the green wire from the hood Use approved methods for all connect...

Страница 4: ...the Lamp 1 Unscrew the lamp by turning in a counter clockwise direction and remove from the socket Replace with a PAR16 medium base 45W maximum Halogen lamp Installation is the reverse of removal Fus...

Страница 5: ...AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES...

Страница 6: ...36099 9 1 Fan Switch 5S1418006 10 1 Light Switch 5S1136069 11 1 Name Plate 5S1421006 REPLACEMENT PARTS DIAGRAM Qty Description Replacement Part 12 2 Lamp Holder 5S1145051 13 1 Fuse Outlet Harness 5S11...

Страница 7: ...VOUS D VACUER L AIR VERS L EXT RIEUR NE PAS VACUER L AIR DANS DES ESPACES DANS LES MURS LES PLAFONDS OU LES GRENIERS LES GALERIES TECHNIQUES OU LES GARAGES d Les ventilateurs avec conduits doivent tou...

Страница 8: ...2 New 2 12 8 of 12 SECTION 3 Pr parez la hotte pour l installation 1 D terminez le type de conduits dont vous aurez besoin Ce mod le peut vacuer l air verticalement ou horizontalement par un conduit d...

Страница 9: ...tte fix e posez les maintenant Pour ce faire consultez les instructions de la section traitant des conduits 1 Vissez les 4 vis de montage aux endroits pr alablement marqu s Laissez un jeu d environ 0...

Страница 10: ...ez de la douille Remplacez par une lampe halog ne de base moyenne PAR16 de 45W au maximum L installation est l inverse du d montage Fusible 1 Pour remplacer la fusible tournez vers la droite le dessus...

Страница 11: ...SUME AUCUNE RESPONSABILIT EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUSIBLES DISJONCTEURS OU R CEPTACLES D...

Страница 12: ...6 10 1 Interrupteur de la lampe 5S1136069 11 1 Plaque de nom 5S1421006 TABLEAU DES PI CES DE RECHANGE n Qte Description Pi ces de rechange n 12 2 Support du Lampe 5S1145051 13 1 C blage d alimentation...

Отзывы: