9.10 Timer function
9.10.1 Timing range is 24 hours, and the minimum resolution is 15 minutes.
9.10.2 Timer on. After turning off, the machine will turn on automatically when reaching the setting time.
9.10.3 Timer off. After turning on, the machine will turn off automatically when reaching the setting time.
9.10.4 Timer on/off. After turning off, the machine will turn on automatically when reaching the setting “on” time, and
then turn off automatically when reaching the setting “off” time.
9.10.5 Timer off/on. After turning on, the machine will turn off automatically when reaching the setting “off” time, and
then turn on automatically when reaching the setting “on” time.
9.10.6 The tolerance of timer is 1 minute per hour.
9.11 Sleep function mode
9.11.1 Operation time in sleep mode is 7 hours. After 7 hours the machine quits this mode and turns off.
9.11.2 In cooling or auto mode sleep function is available.
9.11.3 Operation process in sleep mode is as follow:
1) After pressing ECONOMIC or SLEEP button on controller, the machine will turn into sleep mode.
2) When cooling, the setting temperature rises 1
℃
(be lower than 30
℃
) every one hour, 2 hour later the
rising stops and indoor fan is fixed as low speed.
9.11.4 If user uses timer on function in sleep mode, sleep function will pause and not resume until reaches the setting
on time.
9.11.5 When user uses timer off function in sleep mode(or sleep function in timer off mode), if the timing time is less
than 7 hours, sleep function will be cancelled when reaching the setting time. If the timing time is more than 7
hours, the machine will not stop until reaches the setting off time in sleep mode.
9.12 Auto-Restart function
The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart module. In case
of a sudden power failure, the module restores the setting conditions before the power failure. The unit will resume the
previous operation setting (not including Swing function) automatically after 3 minutes when power returns.
9.13 Ionizer/Plasma dust collector function(optional)
The indoor unit is equipped with Ionizer, which is controlled by the CLEAN AIR button on the remote controller
when the unit is turned on. Press the CLEAN AIR button to activate the function. Press it again to stop the
function. During the time when Ionizer being controlled by remote controller, Ionizer will be turned off
automatically, if indoor fan stops running due to malfunctions or anti-cold-wind. When indoor fan restarts after
malfunctions being eliminated and anti-cold-wind being released, Ionizer will be available again.
10. Troubleshooting
Safety
Because of there are capacitors in PCB and relative circuit in outdoor unit, even shut down the power supply,
electricity power still are kept in capacitors, do not forget to discharge the electricity power in capacitor.
Содержание A17CI4C4M09
Страница 10: ...8 4 Specification Please see the special file about the specifications 5 Refrigerant cycle diagram Cooling only...
Страница 11: ...9 6 Wiring diagram 6 1 Indoor Unit MSC 09CRDN1 NR0 MSC 12CRDN1 NR0 MSC 18CRDN1 NQ0...
Страница 12: ...10 MSC 24CRDN1 NQ0W 6 2 Outdoor Unit MOA 09CDN1 NR0...
Страница 13: ...11 MOB 12CDN1 NR0...
Страница 14: ...12 MOC 18CDN1 NQ0...
Страница 35: ...33 K...