25
PART NAMES
INSTALLATION
USING THE SYSTEM
APPENDIX
SETTING AND ADJUSTMENT
USING THE SECURITY FUNCTION
This function is available when the inputs 1, 2, and/or 3 of the master station are set to “SECURITY”, and a sensor is connected to
*
each of the inputs.
The security mode can be set and activated on the
master station. The following two security modes are
available.
■
ARMED
Security mode when you are present.
The alarm gets enabled when the security mode is turned
active.
■
ARMED AWAY
Security mode when you leave home/of
fi
ce. Set a delay time
for the alarm to enable after the security mode is activated.
When a sensor is trigered
A message is displayed, the sensor ID number is shown,
the status LED blinks in red and an alarm sounds on all the
residential stations.
NOTES:
The alarm sounds in the maximum volume (10) even if the volume
•
of call tone is set to 0.
Door station 1 also sounds alarm and turns on the white LED.
•
All the functions of this station are available while security is on.
•
To stop alarm
When “ARMED AWAY” mode is activated and the delay time
*
is set; if a sensor is triggered before the delay time elapses,
the preliminary alarm sounds. The alarm sounds after the
delay time elapses.
[When there is no ALARM PIN]
Touch RESET .
[When there is an ALARM PIN]
The ALARM PIN can be set on the master station only.
*
Touch
1
RESET .
Enter the ALARM PIN and touch
2
ENTER .
This station turns into the standby mode.
If a wrong ALARM PIN has been entered, an error
*
message is displayed. Enter correct ALARM PIN.
Sensor
Blinks in red.
Alarm