5.3 SHUT-OFF INFORMATION LED
LED Color
UBX-T State
Green
Fastening OK
Orange
Fastening in Progress
Red
Incomplete job detection (turned the trigger from ON to OFF
before automatic shut-off), or UBX-T was stopped by heat
protection function.
Red and green
blink in turns
Battery level is less than 5% or battery error
Red and orange
alternating
Tool is protected from overload, over discharge, or excessive
battery pack temperature.
WARNING
A heat protection feature stops the tool when
the motor gets too hot, regardless of relief valve
shut-off presets. Refer to the following instructions
regarding heat protection.
Heat Protection
When the tool gets hot, the LED lights red and the tool stops
rotation. Avoid use for at least 30 minutes. Once the tool has
cooled to room temperature, and the LED is off, it is safe to restart
operation.
Work Interval Guideline
Following the fastening conditions shown in “5.2 Torque
Adjustment” on page 13, a UBX will be able to fasten at least 8
fasteners a minute, with no downtime, before the heat protection
feature will trigger.
Avoid continuous work or heavy load, which overburdens the
motor.