13
5.2 TORQUE ADJUSTMENT FOR INDIVIDUAL FASTENERS
(clockwise operation only)
1. Remove hand from trigger and remove battery pack from tool
before adjustment.
2. Press anvil to the opposite side and turn it until the relief valve is
visible from the adjusting window.
3. Insert allen key through adjusting window and stick it in the relief
valve’s hole as the below arrow is pointing. Adjust relief valve as
per the following torque range.
Anvil
Liner Assembly
Relief Valve
(Adjusting Screw)
Torque Ranges
Model
Relief Valve Position
Full relaxed to left / full fastened to right
UBX-T70
25 Nm – 55 Nm
Testing Conditions: Torque range was obtained by fastening UFT testers with a hard
joint setting. Torque observed by actual fastening does not correspond to the
above torque range due to conditions of work character and bolt seating surface.