66
Remote Interface Setup
Pressing
remote
…
calls the
REMOTE SETUP
screen which permits RS232/GPIB choice
and selection of address and Baud rate. Full details are given in the Remote Operation section.
Reference Clock In/Out Setting
The function of the rear panel REF CLOCK IN/OUT socket is set on the
REF. CLOCK I/O
screen, called by pressing the
ref. clock i/o
soft
−
key.
REF. CLOCK I/O:
♦
input
◊
output
◊
phase lock
The default setting is for the socket to be set to
input
, i.e. an input for an external 10MHz
reference clock. When set to
input
the system is automatically switched over to the external
reference when an adequate signal level (TTL/CMOS threshold) is detected at REF CLOCK
IN/OUT but will continue to run from the internal clock in the absence of such a signal.
With the clock set to
output
a buffered version of the internal 10MHz clock is made available
at the socket.
With
phase lock
selected the socket can be set to be a
master
or
slave
when
used
for synchronising (phase
−
locking) multiple generators. See Synchronising Generators
section for full details.
Cursor/Marker Output
Pressing the
cursor/marker
…
soft
−
key calls the
CURSOR/MARKER OUTPUT
screen.
CURSOR/MARKER OUTPUT
amplitude: 2V
◊
polarity: negative
◊
cursor width: 1
The cursor/marker signal is output from the rear panel CURSOR/MARKER OUT socket. It is
used as a marker in sweep mode or as a cursor in arbitrary waveform mode. It can be used to
modulate the Z
−
axis of an oscilloscope or be displayed on a second ‘scope channel.
With
amplitude
selected the cursor/marker level can be set between 2 and 14V in 2V steps.
With
polarity
selected the polarity can be set
positive
or
negative
. With
polarity
set to
positive
the cursor/marker is a positive
−
going pulse from the 0V
baseline; with
polarity
set to
negative
the cursor/marker is a negative
−
going pulse
from the 2
−
14V set amplitude level, i.e.
negative
gives an inverted signal.
When used as a sweep marker (i.e. Sweep mode selected) the width is determined by the time
spent at the marker frequency, see Sweep Marker in the Sweep Operation section for details.
When used as a cursor during arbitrary waveform editing (i.e.
edit waveform
selected on
the
MODIFY
screen) the width can be adjusted by repeated presses of the
cursor width
soft
−
key or by using the rotary control. The width is adjustable so that the cursor can still be
made visible even with long arbitrary waveforms. The width is always an odd number of
waveform points increasing in steps of 2 points from 1 to 3, 5, 7, etc. A
width
setting of 1
corresponds to 1 waveform point,
width 2
is 3 points,
width 3
is 5 points and so on
up to
width 30
which is 59 points.
Содержание TGA1240 Series
Страница 1: ...TGA1240 Series 40MHz Arbitrary Waveform Generators INSTRUCTION MANUAL ...
Страница 101: ...100 Block Diagrams ...
Страница 102: ...101 Front Panel Diagrams ...