4.3 Mounting
This unit is designed to mount to a two gang deep electrical box
(see
Figure 2
) or the unit can be mounted to a ceiling or wall without a gang
box (see
Figure 3)
.
Figure 2 Two-Gang Electrical Box Mount
4.2.1 Connecting Low Voltage Power
1.
Prepare the camera’s low voltage wires by stripping 9-11 mm (0.39 inch)
from each wire.The push-wire connector is designed to accommodate
AWG 20-16 wire.
2.
Connect the line and neutral wires.To connect, press the button on the
connector fully as indicated on the connector. Insert the stripped
conductor into the square entry and release.
3.
DC Applications
: The neutral/common wire for 12 VDC supply is to be
installed in the connector on the black wire.The 12 VDC supply wire is to
be installed in the connector on the red wire.
AC Applications:
The camera’s operation is not effected by the polarity
of the 24 VAC wires. However in multiple camera systems consistent
wiring configurations will help maintain roll-free switching.
4.2.2 Connecting Video Cable
1.
Route and connect video cable to BNC connector.
ø .87
22,1
2. Place 2 screws through the unit's slotted
screw holes and mount directly to the gang box.
1. Remove two screws and discard back plate. ( Not Shown)
3. After making camera adjustments, replace the dome cover to the unit.