4. INSTALLATION
Attention: Installations should be performed by qualified service personnel
only in accordance with the National Electrical Code or applicable local codes.
Model No.
Voltage Range
Power
PAL Models
21 to 27 VAC, 50 Hz or 11 to 13 VDC
2.7 W
NTSC Models
21 to 27 VAC, 60 Hz or 11 to 13 VDC
2.7W
4.1 Preparing the Unit
Remove the integrated camera/dome unit from the carton. Feed wires through
opening and if necessary, break tab.
4.2 Connecting Low Voltage Power & Video Signal
The wiring harness will have a BNC connector to accept video coax and two
push-wire connectors to accept the low voltage power. For mounting to an
electrical box, run power and video lines through a knockout into the box
(not provided). For mounting directly to a wall or ceiling, run power and video
lines via conduit to the desired location.
Caution: Before proceeding, be sure to disconnect the power from the cable
to be installed into the unit. Be sure that the unit is of the proper voltage
type for the line power being used.
7
3. DESCRIPTION
The MLAR Series Domes are small, discreet surveillance domes containing
high performance 1/4-inch CCD cameras.
Figure 1 Dome Assembly
Power Board
Camera Assembly
Recessed Can Assembly
BNC & Power Connector
Dome Cover Assembly