IMPORTANT:

If mounting outdoors, or after servicing add a generous

seal/bead of RTV or silicone around the cables (on the inside of the

conduit) either at the camera or at the junction box. This will help

reduce moisture accumulation in the dome over long periods of time.

4. If mounting this unit outdoors or after servicing, apply a generous bead of

silicone sealant around the back of the base casting, surrounding all holes.

Apply the rubber base gasket to the back of the base casting and apply

another generous bead of sealant to the outer edge around the exposed

surface of the gasket.

5. Place the unit into position on the wall or ceiling. Install the mounting

screws securely. If sealant is used, make sure that the sealant between the

wall or ceiling and the gasket forms a complete seal.Add more sealant if

needed. Make all final service connections and secure the conduit.

Important Note on Service:

1. When servicing the unit reapply silicon lubricant to the rubber gasket

between the lid and cover before replacing the cover.

2. When replacing the cover make sure the gasket is aligned with the

housing to ensure a proper seal.

5.3 Mounting and/or Servicing the Unit

Refer to

Figure 1

.

1. Using the rubber base gasket as a template, mark the mounting hole

locations on the mounting surface.The unit is intended to be mounted

with four #10 screws or four M5 screws (not supplied) through the four

outer holes in the base casting.

2. Install the appropriate anchors or threaded fasteners.
3. Install a 3/4-inch threaded service conduit coupling into the back conduit

hole, using pipe sealant on the threads. If conduit is to enter from the

side, use a 2-mm Allen wrench to loosen the set screw from the conduit

hole plug. Remove the plug and reinstall it in the conduit hole on the back

of the unit.

Содержание MLA Series

Страница 1: ...Tilt an Sq MLA SERIES OUTDOOR DOMES MLA2CH211 MLA2WD211 MLA2DN211 I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W A I G I S M E C H C O M y...

Страница 2: ...ance Attention Installation should be performed by qualified service personnel only in accordance with the National Electrical Code or applicable local codes 24 VAC Units Do Not Exceed 30 VAC Input Vo...

Страница 3: ...ce qualifi conform ment la r glementation du Code Electrique National ou la r glementation locale Appareils 24 VCA Ne pas exc der 30 VCA La tension appliqu e l entr e d alimentation de l ap pareil ne...

Страница 4: ...l gem jeweilig zutreffender Elektrovorschriften ausgef hrt werden 24 VAC Ger te Achtung 30 Volt Eingangswechselspannung darf f r 24 VAC Modelle nicht berschritten werden Normal betrieb findet bei 24 V...

Страница 5: ...ersonal capacitado solo en acuerdo y en cumplimiento de nor mas del National Electric Code C digo El ctrico Nacional las normas del Gobierno Nacional Local Unidades de 24 VCA No exceder 30 VCA de entr...

Страница 6: ...r may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government...

Страница 7: ...with the threaded posts in the base fit the cover onto the base and tighten the retaining screws securely 5 INSTALLATION Attention Installations should be performed by qualified service personnel onl...

Страница 8: ...ly wires into the 2 position terminal block supplied and tighten with a flat blade screwdriver Connect Video cable to the unit s BNC connector 5 2 Connecting Low Voltage Power Video Signals UTP Models...

Страница 9: ...more sealant if needed Make all final service connections and secure the conduit Important Note on Service 1 When servicing the unit reapply silicon lubricant to the rubber gasket between the lid and...

Страница 10: ...osen Thumbnuts x3 3 Make Pan adjustment by turning camera bracket in clockwise or counter clockwise motion 4 Tilt Lens into position then rotate face plate to square image 5 Tighten Thumbnuts Figure 3...

Страница 11: ...t Kit Placement Zoom Knob Focus Knob Desiccant Kit Placement RJ45 Jack U units only 7 LENS ADJUSTMENT 7 1 Adjustment Of Variable Focus Lens 1 Remove the dome cover before lens adjustment 2 Turn the zo...

Страница 12: ...nics 1124 Louise Road Winston Salem NC 27107 5450 Tel 336 785 7740 Fax 336 785 7744 Data subject to change without notice 97 8 153 5 6 04 79 3 11 135 6 5 34 3 85 61 1 2 41 153 5 6 04 144 3 5 68 Thread...

Отзывы: