Remove Cap, fill Bulb full of warm soapy water, replace Cap 
and force water through Tubing by gently squeezing the Bulb.

Remove Cap, refill with clean water, replace Cap and again, 
gently squeeze the Bulb to force water through the Tubing.

Completely disassemble the FingerFeeder and clean all parts 
(except Tape) with warm soapy water.

Rinse parts well and allow to air dry on a clean towel. (It may 
help to reassemble the device and gently squeeze the empty 
Bulb a few times to remove water droplets from the Tubing).

1. 

2. 

3. 

4. 

Cleaning Instructions

After each use:

Once per day:

This device may be sterilized or sanitized by using the following 
instructions. 

Sterilization:

All disassembled parts can be autoclaved to a maximum of 272° 
for 3 minutes at 29 PSIG  or 250° F for 15 minutes at 15 PSIG. 

To  avoid damage during and immediately after sterilization:
 

• Sterilize without applying external pressure on parts.

 

• Allow  parts  to  cool before  applying  external pressure. 

If gas sterilization is  used, residual  testing  is  recommended  to 
determine the proper length of aeration.

Sanitization:

• Place parts in a 4-5 quart pan.
• Fill to within 1inch of rim with cold water. Distilled water is preferred, to reduce hard water deposit 
  formation.
• Cover pan and bring water to a boil. 
• Boil parts for 20 minutes.
• Remove pan from heat.
• Drain water and allow parts to cool in open pan.
• Remove all parts and allow to air dry on a clean towel. 
• Avoid touching the inside of the Bulb.

Содержание Hazelbaker FingerFeeder

Страница 1: ...Instructions Assembly HazelbakerTM FingerFeeder ...

Страница 2: ...oses weight or has fewer than 2 bowel movements and 6 8 wet diapers every 24 hours contact your physician immediately Consult with your health care professional regarding your baby s progress throughout the time you use your FingerFeeder YOUR DOCTOR Your physician or other primary health care provider should know that you are using the Hazelbaker FingerFeeder so that he she can provide you with th...

Страница 3: ...ng the following instructions Sterilization All disassembled parts can be autoclaved to a maximum of 272 for 3 minutes at 29 PSIG or 250 F for 15 minutes at 15 PSIG To avoid damage during and immediately after sterilization Sterilize without applying external pressure on parts Allow parts to cool before applying external pressure If gas sterilization is used residual testing is recommended to dete...

Страница 4: ...the Tubing may be gently pulled up straight through the slit Avoid pulling with too much force to prevent damaging tubing 2 Gently pull the Tubing into the slit of the Tubing Clamp to prevent milk flow 3 From the side of the Disc opposite the Finger Grip push the stem of the White Membrane all the way through the small opening until the White Membrane is flush with the Disc 4 Hold the Bulb in a ve...

Страница 5: ...ace the Bulb in the palm of the hand Position the Tubing to Bulb junction between the Tubing Clamp and the palm of the hand This will allow less air to get into the tubing and the baby 7 Place Tubing along the palm side of your finger Position the end of the Tubing even with the end of your finger To prevent tape from getting into the baby s mouth secure the Tubing to your finger by taping it betw...

Страница 6: ... baby sucks gradually move your finger back to the juncture of the hard and soft palate While moving the finger back keep the pad in contact with the hard palate Keep your finger pad resting up against the hard palate during the entire feed If your finger goes too far back or drops down on baby s tongue baby may gag Keep your finger in the same position and stationary Do not apply pressure to baby...

Страница 7: ......

Страница 8: ...va llc 5115 Olentangy River Road Columbus OH 43235 Phone 1 614 451 1154 Hazelbaker is a trademark of Alison Hazelbaker Aidan Éva is a registered trademark of Aidan Éva llc Patent No D392038 2020 Aidan Éva llc ...

Отзывы: