16  Troubleshooting 

 
In the event you encounter a trouble that could be caused by a failure of the meter, refer to the 
following table first. If the symptom is not listed in this table or the measures in this table does not 
improve the situation, contact your nearest branch office or sales office.   
 

Symptoms 

Possible causes 

Corrective actions 

No pulse is output. 

The external connection cable was 
wrongly wired. 

Check that the pulse outputs (unit 
pulse/high-density pulse) are properly connected 
in the correct polarity. Refer to Chapter 9, 
External connection for how to connect the cable.

The external connection cable has 
broken. 

Repair the broken part, or replace the external 
connection cable. 

The connecter part of the external 
connection cable has broken because its 
sheathed part was rotated during the 
connection/disconnection of the 
connector. 

Be sure to rotate the metal ring at the tip of the 
connector.  
Since the connector part has broken, the external 
connection cable has to be replaced. 

The display turns off. 

The external connection cable was 
wrongly wired (applicable only for the 
external power source type). 

Check that the power source is correct in voltage 
and polarity. Refer to Chapter 9, External 
connection for how to connect the cable. 

The external connection cable has 
broken (applicable only for the external 
power source type). 

Repair the broken part, or replace the external 
connection cable. 

The circuit board became moist due to 
rainwater or other liquid, which led to a 
short circuit. 

This product is not a waterproof design. Be 
careful not to let water get into the display. 

Due to a lightning-induced impulse, an 
overvoltage was applied to the internal 
circuit board, which caused a breakdown 
in the circuit board. 

Since the internal circuit board has a failure, the 
meter main body has to be replaced. 

The most significant 
digit of the integrated 
flow rate display is 
blinking. 

The voltage of the battery has reduced 
(applicable only for the Built-in battery 
type). 

The blink indicates that the battery is running 
down.  
The meter body has to be replaced. 

The display cannot be 
changed with a switch. 

The switch has broken down because 
firm pressure was placed on it with a 
hard object such as a mechanical pencil 
and screwdriver. 

Since the switch has broken down, the meter 
body has to be replaced. Operate switches with a 
soft object, such as the tip of a finger. 

The circuit board became moist due to 
rainwater or other liquid, which led to a 
short circuit and caused the 
microcomputer to malfunction. 

This product is not a waterproof design. Be 
careful not to let water get into the display. 

The integrated flow 
rate value is increasing 
in spite of the absence 
of a gas flow. 

Noises incoming from the external 
connection cable caused the 
microcomputer to malfunction. 

Place the meter away from other signal wires. 
Use a shielded wire as the extension wire to the 
remote indicator. In addition, install a pulse 
converter to isolate the transmitter circuit and the 
receiver circuit. 

-   The integrated flow 

rate value does not 
increase.  

-   The flow rate of the 

meter main body is 
smaller than the 
actual flow rate. 

The meter is being used out of the 
specified flow rate range, so that the 
actual flow rate cannot be measured 
correctly. 

Use the meter main body in the specified flow 
rate range. 

The impeller cannot rotate correctly 
because a foreign object has adhered to 
the impeller. 

Following Chapter 13, Instructions for inspection, 
inspect the meter main body and remove the 
foreign object. In addition, clean the inside of the 
pipes and install a strainer upstream from the 
meter main body. 

The impeller cannot rotate correctly 
because a foreign object in a pipe has 
got into the bearing. 
The impeller cannot rotate correctly 
because drain or water has got into the 
bearing. 

The meter cannot be installed where drain or 
water is supplied. 

 
 

Содержание TBX100

Страница 1: ...wer Source Type TBX30D TBX100D TBX100FD TBX150FD Thank you for purchasing this product Please read through this instruction manual carefully and use the product properly The warranty is on the back co...

Страница 2: ...proper use of the turbine gas meter for management and control this instruction manual contains various pictograms intended to prevent injuries to you and other people or damage to property Those pic...

Страница 3: ...rformance or damaged Contact us before measuring a special gas 3 Do not give an impact to the meter Do Not The meter is a precision measuring instrument Do not give a strong impact to the meter or hit...

Страница 4: ...Do 2 The orientation markings on the main body of the meter must be the same as the direction of the gas flow Do 3 Straight pipes having a length of 10D i e 10 times the pipe diameter or greater must...

Страница 5: ...nuts softly before tighten them in an even crisscross pattern applicable for TBX100F D and TBX150F D Tightening torque 100 N m max Secure the minimum design fastening pressure recommended by the gask...

Страница 6: ...your nearest branch office or sales office Name or model Appearance Quantity Remarks Built in battery type External power source type Standard items Turbine meter main body 1 For the model name refer...

Страница 7: ...urce type L Left inlet left to right R Right inlet right to left U Bottom inlet bottom to top D Top inlet top to bottom 3 32A Rc 11 4 4 40A Rc 11 2 Integrated flow rate display Instantaneous flow rate...

Страница 8: ...4 Rc 1 1 2 Rc 2 JIS 10K Flange 50A Operating temperature range C 10 to 60 Installation angle Horizontal and vertical Measurable gas 1 City gas 2 LP gas 2 air nitrogen Power source Built in battery ty...

Страница 9: ...e output width Approx 13 ms Approx 9 ms Approx 11 ms Maximum ON current 10 mA Maximum ON resistance 2 100 Maximum frequency Approx 75 Hz Approx 110 Hz Approx 90 Hz Maximum applied voltage 24 VDC 1 Uni...

Страница 10: ...ironments approx 60 C The battery cannot be replaced 1 Applicable only for Built in battery type products When the remaining battery life becomes less than about one month a running down battery alarm...

Страница 11: ...only used Terminal box For indoor communication wires 4 terminals 2 External power source type External connection cable Use the dedicated external connection cable to supply a 12 to 24 VDC power and...

Страница 12: ...Description Red Black White Blue Yellow Green Power supply 12 to 24 VDC Power GND Unit pulse Unit pulse High density pulse High density pulse Terminal box optional The terminal box is used when the ex...

Страница 13: ...er 8 Use caution not to let foreign objects such as weld tips foreign objects and sealant enter during the installation of pipes 9 Do not install this turbine meter at a place where it is subjected to...

Страница 14: ...Rotate the counter 180 degrees C Rotate the mounting plate 90 degrees to secure it Use the attached screws 3 Secure the counter again The display can have an angle up to approximately 10 degrees A Rem...

Страница 15: ...value Pressing and holding the switch continuously for three seconds or longer will change the display to an integrated flow rate value Instantaneous flow rate switch Trip flow rate switch While an in...

Страница 16: ...as not been completed the constant data to be used is the previous setting value The following figure shows the flow of constant setting and display Constant display mode Press and hold the FLOW RATE...

Страница 17: ...letion of setting to confirm the setting value and then the display will return to the item selection current setting value display The following figure shows the overview of setting flow Press the FL...

Страница 18: ...output width between 40 and 120 1 Press the FLOW RATE switch Press and hold the FLOW RATE switch for two seconds confirmation of setting 5 Pulse output width setting current setting value display Pres...

Страница 19: ...etection of the power failure is restored and the integration is resumed from that value The product has the inventory mode for reducing the power consumption while it is in stock In the inventory mod...

Страница 20: ...he pilot does not blink in spite of the presence of a gas flow detach the meter from the pipes and then gently blow air into the inlet of the meter to check whether or not the pilot on the indicator b...

Страница 21: ...t in battery type 4 wires External power source type 6 wires Terminal box optional Extension wire 200 m max Use a steel conduit tube as an anti noise measure Built in battery type External connection...

Страница 22: ...ate m3 h Instantaneous flow rate m3 h Pressure loss Pa Pressure loss Pa Pressure loss Pa Instrumental error Instrumental error Turbine meter TBX100 D TBX100F D general performance diagram low pressure...

Страница 23: ...The most significant digit of the integrated flow rate display is blinking The voltage of the battery has reduced applicable only for the Built in battery type The blink indicates that the battery is...

Страница 24: ...damage due to a human made disaster flood damage earthquake lightening or other natural disaster pollution or abnormal voltage 4 Lack of presentation of this warranty 5 Malfunction or damage due to t...

Отзывы: