11  Functions 

 

 

Caution 

When operating the switches, be careful not to place firm pressure on them with a hard 
object such as a mechanical pencil and screwdriver because it may cause a failure of the 
switches. Press them with a soft object, such as the tip of a finger. 

 

Normal mode and constant display mode 

 

 

Category

 

Model

 

Name

 

TBX30 (D) 

TBX100 (D) 

TBX100F (D) 

TBX150F (D) 

Switch 

part

 

 

Instantaneous flow 

rate switch 

While an integrated flow rate value is displayed: 

Pressing the switch (for less than one second) will display an instantaneous flow rate value.
Thirty seconds later, the display will automatically return to an integrated flow rate value. 

While an instantaneous flow rate value is displayed: 

Pressing and holding the switch (continuously for one second or longer) will change the 
display to the previous one prior to the latest switching (instantaneous flow rate display or 
trip flow rate display).   
When the display changes to a trip flow rate value, the value will not be reset. 

While a trip flow rate value is displayed: 

Pressing the switch (for less than one second) will display an instantaneous flow rate value.
Thirty seconds later, the display will automatically return to a trip flow rate value.

 

 

Trip flow rate switch 

While an integrated flow rate value or instantaneous flow rate value is displayed: 

Pressing the switch (for less than three seconds) will display an integrated flow rate value 
from the moment (trip flow rate).   

While a trip flow rate value is displayed: 

Pressing the switch (for less than three seconds) will reset the trip flow rate value. Pressing 
and holding the switch (continuously for three seconds or longer) will change the display to 
an integrated flow rate value.

 

Instantaneous 

flow rate switch 

+  

Trip flow rate 

switch

 

While an integrated flow rate value, instantaneous flow rate value, or trip flow rate value is 
displayed: 

Pressing and holding the switches together (continuously for four seconds or longer) will 
change the mode to the constant display mode. 
Pressing and holding the switches together (continuously for ten seconds or longer) will 
change the mode to the inventory mode. (*) 

Constant display mode: 

Pressing and holding the switches together (continuously for ten seconds or longer) will 
change the mode to the inventory mode. (*) For details, refer to 1) Constant display mode 
through 4) Pulse output setting conditions.   

Inventory mode (*) 

Pressing and holding the switches together (continuously for two seconds or longer) will 
change the display to an integrated flow rate value. For details, refer to 5) Inventory mode.

Display 

part 

Integrated flow rate 

(m

3

Instantaneous flow 

rate (m

3

/h) 

Trip flow rate (m

3

Pilot 

 Blinking 

Indicates that a gas is measured when it is 
flowing. 
The lamps repeatedly turn on from the left. 

 

Normal mode

 

 

 

Press and hold for 1 

second, or let stand 

for 30 minutes

 

Instantaneous 

flow rate display

 

Integrated flow rate 

display 

Press and hold 

for 3 seconds

Trip flow rate display

Press and hold for 1 

second, or let stand 

for 30 minutes

 

(*2)   The trip flow rate value 

is reset. 

Press and hold for 

4 seconds

Press and hold for 

10 seconds (*1) 

Press and hold for 

2 seconds (*1)

Constant display mode 

For details, see the next page.

Press and hold for 

10 seconds (*1) 

Inventory mode (*1) 

(*1)  Applicable only for the 

Built-in battery type

(*)  Applicable only for the Built-in battery type

Содержание TBX100

Страница 1: ...wer Source Type TBX30D TBX100D TBX100FD TBX150FD Thank you for purchasing this product Please read through this instruction manual carefully and use the product properly The warranty is on the back co...

Страница 2: ...proper use of the turbine gas meter for management and control this instruction manual contains various pictograms intended to prevent injuries to you and other people or damage to property Those pic...

Страница 3: ...rformance or damaged Contact us before measuring a special gas 3 Do not give an impact to the meter Do Not The meter is a precision measuring instrument Do not give a strong impact to the meter or hit...

Страница 4: ...Do 2 The orientation markings on the main body of the meter must be the same as the direction of the gas flow Do 3 Straight pipes having a length of 10D i e 10 times the pipe diameter or greater must...

Страница 5: ...nuts softly before tighten them in an even crisscross pattern applicable for TBX100F D and TBX150F D Tightening torque 100 N m max Secure the minimum design fastening pressure recommended by the gask...

Страница 6: ...your nearest branch office or sales office Name or model Appearance Quantity Remarks Built in battery type External power source type Standard items Turbine meter main body 1 For the model name refer...

Страница 7: ...urce type L Left inlet left to right R Right inlet right to left U Bottom inlet bottom to top D Top inlet top to bottom 3 32A Rc 11 4 4 40A Rc 11 2 Integrated flow rate display Instantaneous flow rate...

Страница 8: ...4 Rc 1 1 2 Rc 2 JIS 10K Flange 50A Operating temperature range C 10 to 60 Installation angle Horizontal and vertical Measurable gas 1 City gas 2 LP gas 2 air nitrogen Power source Built in battery ty...

Страница 9: ...e output width Approx 13 ms Approx 9 ms Approx 11 ms Maximum ON current 10 mA Maximum ON resistance 2 100 Maximum frequency Approx 75 Hz Approx 110 Hz Approx 90 Hz Maximum applied voltage 24 VDC 1 Uni...

Страница 10: ...ironments approx 60 C The battery cannot be replaced 1 Applicable only for Built in battery type products When the remaining battery life becomes less than about one month a running down battery alarm...

Страница 11: ...only used Terminal box For indoor communication wires 4 terminals 2 External power source type External connection cable Use the dedicated external connection cable to supply a 12 to 24 VDC power and...

Страница 12: ...Description Red Black White Blue Yellow Green Power supply 12 to 24 VDC Power GND Unit pulse Unit pulse High density pulse High density pulse Terminal box optional The terminal box is used when the ex...

Страница 13: ...er 8 Use caution not to let foreign objects such as weld tips foreign objects and sealant enter during the installation of pipes 9 Do not install this turbine meter at a place where it is subjected to...

Страница 14: ...Rotate the counter 180 degrees C Rotate the mounting plate 90 degrees to secure it Use the attached screws 3 Secure the counter again The display can have an angle up to approximately 10 degrees A Rem...

Страница 15: ...value Pressing and holding the switch continuously for three seconds or longer will change the display to an integrated flow rate value Instantaneous flow rate switch Trip flow rate switch While an in...

Страница 16: ...as not been completed the constant data to be used is the previous setting value The following figure shows the flow of constant setting and display Constant display mode Press and hold the FLOW RATE...

Страница 17: ...letion of setting to confirm the setting value and then the display will return to the item selection current setting value display The following figure shows the overview of setting flow Press the FL...

Страница 18: ...output width between 40 and 120 1 Press the FLOW RATE switch Press and hold the FLOW RATE switch for two seconds confirmation of setting 5 Pulse output width setting current setting value display Pres...

Страница 19: ...etection of the power failure is restored and the integration is resumed from that value The product has the inventory mode for reducing the power consumption while it is in stock In the inventory mod...

Страница 20: ...he pilot does not blink in spite of the presence of a gas flow detach the meter from the pipes and then gently blow air into the inlet of the meter to check whether or not the pilot on the indicator b...

Страница 21: ...t in battery type 4 wires External power source type 6 wires Terminal box optional Extension wire 200 m max Use a steel conduit tube as an anti noise measure Built in battery type External connection...

Страница 22: ...ate m3 h Instantaneous flow rate m3 h Pressure loss Pa Pressure loss Pa Pressure loss Pa Instrumental error Instrumental error Turbine meter TBX100 D TBX100F D general performance diagram low pressure...

Страница 23: ...The most significant digit of the integrated flow rate display is blinking The voltage of the battery has reduced applicable only for the Built in battery type The blink indicates that the battery is...

Страница 24: ...damage due to a human made disaster flood damage earthquake lightening or other natural disaster pollution or abnormal voltage 4 Lack of presentation of this warranty 5 Malfunction or damage due to t...

Отзывы: