background image

2

Chapter 1. Product Features

SB302-LB User Manual

1.2 Specifications

Dimensions 

(W x D x H)

mm : 430 x 680 x 132.8

inches : 17 x 26.8 x 5.2

Motherboard 

AIC Server Board Libra 

Processor 

Processor 

Support 

• Two Intel® Xeon® Processors 

  E5-2600 v3/v4 product family

• Supports CPU TDP up to 85W

QPI Speeds

9.6 GT/s, 8 GT/s, 7.2 GT/s

Socket Type

Socket R3 (FCLGA2011-3)

Chipset Support 

Intel® C612 Chipset

System Memory 

• 16 DIMM slots across 8 memory channels 

  (4 memory channels per CPU; 2DPC)

- 512GB DDR4 2400/2133 RDIMM DRx4

- 128GB DDR4 2400/2133 RDIMM SRx4

- 1024GB DDR4 2400/2133 LRDIMM QRx4

- 2048GB DDR4 2400/2133 LRDIMM 3DS 8Rx4

Front Panel 

• System power on/off

• System ID

• System reset

• 2 x USB 3.0 Type A

LEDs

• Power status

• System alert

• LAN activity

• Drive activity

• System ID

Drive Bays

External

3.5" hot swap

16

2.5” hot swap

Options :

• 2 x 2.5” hot swap

• 2 x 2.5” internal

Internal

2.5”

Backplane

Options

1 x 16-port 12Gb SAS backplane with 

28-PHY expander chip and 3 SFF-8643 

connectors

1 x 16-port 12Gb SAS backplane with 4 

SFF-8643 connectors

Expansion Slots

PCIe 3.0

• 2 x16 slots (FH)

• 1 x16 slot (x8 mode w/ IOC SKU) (FH)

• 3 x8 slots (FH)

System BIOS 

BIOS Type

• Insyde UEFI BIOS

• SPI (Serial Peripheral Interface) 

  FLASH Interface

BIOS 

Features

• ACPI 

• PXE 

• WOL

• AC loss recovery

• IPMI 2.0 KCS  

  interface

• SMBIOS 

• Serial console   

  redirection

• BIOS Boot 

• BIOS Recovery 

  Mode

• SRIOV

• iSCSI

• TPM

• PCIe NTB

On-board 

Devices

SATA

Built-in SATA controller with RAID support 

on Intel® C612 Chipset

• 8 x 7pin SATA connectors

• 1 x M.2 with SATA/PCIe X4 support

IPMI

Aspeed AST2400 Advanced PCIe Graphics & 

Remote Management Processor

• Baseboard Management Controller

• Intelligent Platform Interface 2.0 (IPMI 2.0)

• iKVM, Media Redirection, IPMI over LAN, 

  Serial over LAN

• SMASH Support

Network 

Controllers

• Intel® Ethernet Controller X540-BT2 dual 

  port 10GbE, 10GBASE-T, PCIe v2.1, x8

  [Or Intel® Ethernet Controller I350-AM2,  

  dual port GbE, PCIe v2.0 (co-lay with   

  Intel® X540-BT2). MOQ required.]

• Intel® Ethernet Controller I210-AT, single

  port GbE controller, PCIe v2.1, 2.5 GT/s, x1

• Intel® Ethernet Network Connection

  I217-LM, single port GbE, 1Gbps

• Realtek® RTL8201EL single port 10/100 Mbps  

  Ethernet PHYceiver for dedicated BMC port

Graphics

Aspeed AST2400 Advanced PCIe Graphics & 

Remote Management Processor

• PCIe VGA/2D Controller

• 1920x1200@60Hz 32bpp

Rear I/O 

LAN

• 2 x 10GbE RJ45 (or factory option: 2 x GbE) 

• 2 x additional GbE RJ45: optional in PCIe 

  bracket area

• 1 x GbE RJ45 dedicated to BMC management

USB

2 x USB 3.0 Type A 

VGA

1 x external DB-15 VGA port

Serial Port 1 x external DB-9 COM port

Power Supply 

800W 1+1 redundant power supply 80+ Platinum

• AC INPUT : 100~240V,50/60Hz,10-5A

System Cooling 

3 x 80x38mm hot swap fans

System 

Management 

• IPMI 2.0 

• KVM over IP

• Media redirection

• Temperature, fan, voltage, PSU sensor monitor

• System temperature

• System ID / System fail indicator

• Remote power on/off/reset

• SEL message alarm through mail

• SNMP support

• Intel NM

Environmental 

• Storage temperature : -10ºC(14ºF) ~ 60ºC(140ºF)

• Operating temperature : 0ºC(32ºF) ~ 35ºC(95ºF)

• Storage operating humidity : 5%~95% non-condensing

Gross Weight 

(w/ PSU & Rail)

kgs : 30.8 

lbs : 67.9

Packaging 

Dimensions

(W x D x H)

mm : 605 x 920 x 366

inches : 23.8 x 36.2 x 14.4

Mounting 

Standard

28" tool-less slide rail

Содержание SB302-LB

Страница 1: ...UM_SB302 LB_v4_060619 SB302 LB Storage Server Barebone User s Manual...

Страница 2: ...M Installation 17 2 3 Top Cover 18 2 4 Power Supply Unit Module 19 2 4 1 Removing the Power Supply Unit 19 2 5 Fan Module 20 2 5 1 Replacing the Fan 20 2 6 Hard Disk Drive 21 2 6 1 Replacing the Hard...

Страница 3: ...60 4 3 Main 63 4 3 1 Main 63 4 4 Advanced 64 4 4 1 Peripheral Configuration 64 4 4 2 PCH SATA Configuration 65 4 4 3 PCH SSATA Configuration 65 4 4 4 Video Configuration 65 4 4 5 USB Configuration 66...

Страница 4: ...Settings 78 5 1 Method 1 Use the BIOS Setup 78 5 2 Method 2 Use a Dos Tool Syscheck 79 5 3 Connect to BMC 80 5 4 Web UI 81 5 4 1 Dashboard 81 5 4 2 Field Replaceable Unit FRU 82 5 4 3 Server Health 8...

Страница 5: ...Copyright 2015 AIC Inc All Rights Reserved This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements...

Страница 6: ...Document Release History Release Date Version Update Content 2015 1 User s Manual release to public 2018 2 Update June 2018 3 Update June 2019 4 New cover...

Страница 7: ...e for compliance could void your authority to operate the equipment Disclaimer AIC shall not be liable for technical or editorial errors or omissions contained herein The information provided is provi...

Страница 8: ...ly mount the equipment into the rack in such manner that it won t be hazardous due to uneven mechanical loading This equipment is to be installed for operation in an environment with maximum ambient t...

Страница 9: ...not use liquid or detergent for cleaning The use of a moisture sheet or cloth is recommended for cleaning Module and drive bays must not be empty They must have a dummy cover CAUTION The equipment int...

Страница 10: ...ngs This chapter elaborates the overall layout of the server motherboard including multifarious connectors jumpers and LED descriptions These descriptions assist users to configure different settings...

Страница 11: ...are damaged If any damage is found do not remove the components contact the dealer where the subsystem was purchased for further instructions Before continuing first unpack the subsystem and verify t...

Страница 12: ...support IPMI Aspeed AST2400 Advanced PCIe Graphics Remote Management Processor Baseboard Management Controller Intelligent Platform Interface 2 0 IPMI 2 0 iKVM Media Redirection IPMI over LAN Serial...

Страница 13: ...em expansion into to provide greater bandwidth and utilization In addition to the noteworthy features of the barebone SB302 LB provides immediate and efficient management with Onboard Baseboard Manage...

Страница 14: ...Panel Power Button System Power LED System HDD Activity LED LAN1 Power LED LAN2 Power LED System Alert LED System Reset Button Top plate optional 2 x 2 5 internal HDD slim CD R 4 x 2 5 internal HDD 2...

Страница 15: ...5 Chapter 1 Product Features SB302 LB User Manual Rear Panel Options 2 5 x 2 internal HDD 2 5 x 2 hotswap HDD 800W 1 1 redundant PSU 80 Gold Motherboard I O panel Full height PCIe slots x 6...

Страница 16: ...6 Chapter 1 Product Features SB302 LB User Manual Major Components 16 x 3 5 inch hot swap external HDD trays 3 x 8038mm fans 2 5 inch hot swap HDD trays AIC Server Board Libra...

Страница 17: ...giving it two rotations and stop see letter A CAUTION Do not full loosen 1b Proceed to screw 2 and loosen it by giving it two rotations and stop see letter B Similarly loosen screws 3 and 4 Repeat st...

Страница 18: ...and not touching any pins inside the socket Install the socket cover if a replacement processor is not going to be installed R E M O V E R E M O V E L G A 2 0 1 1 3 S U P P L I E R I D E N T I F I C...

Страница 19: ...inappropriate for your server CAUTION ESD and handling processors reduce the risk of electrostatic discharge ESD damage to the processor by doing the following 1 Touch the metal chassis before touchin...

Страница 20: ...letter C Carefully place Do NOT drop the CPU into the socket CAUTION The pins inside the CPU socket are extremely sensitive other than the CPU No object should make contact with the pins inside the CP...

Страница 21: ...se the load plate Step 4 Secure the Load Plate 4a Push downward on the locking lever on the CLOSE 1st side see letter A Slide the tip of the lever under the notch in the load plate see letter B Make s...

Страница 22: ...om front to back of the chassis see letter B 5c Each heatsink has four captive fasteners and should be tightened diagonally using the following procedure 5c 1 Using a 2 Phillips screwdriver start with...

Страница 23: ...sink screws with the screw holes in the motherboard CAUTION Possible thermal damage may occur when moving the heatsink Avoid moving the heatsink after it has contacted the top of the CPU Too much move...

Страница 24: ...IMM Load Reduced DIMM LRDIMM NOTE Salot 1 Slot 3 is available only when JCPU0 processor is installed Slot 2 Slot 4 Slot 5 Slot 6 is available only when JCPU1 processor is installed 2 2 System Memory J...

Страница 25: ...MB0 JDIMMB1 CPU1 CPU0 DIMM Numbers DIMM Arrangement 2 DIMMs CPU1 CPU0 JDIMM_G0 JDIMM _A0 JDIMMF1 JDIMMD1 JDIMMC1 JDIMMC0 JDIMMD0 JDIMMF0 JDIMME1 JDIMME0 JDIMMG0 JDIMMG1 JDIMMH0 JDIMMH1 JDIMMA0 JDIMMA1...

Страница 26: ...1 JDIMMC0 JDIMMD0 JDIMMF0 JDIMME1 JDIMME0 JDIMMG0 JDIMMG1 JDIMMH0 JDIMMH1 JDIMMA0 JDIMMA1 JDIMMB0 JDIMMB1 CPU1 CPU0 CPU1 CPU0 JDIMM_ G0 JDIMM_A0 JDIMM_ G1 JDIMM_A1 JDIMM_ H0 JDIMM_B0 JDIMM_ F0 JDIMM_D...

Страница 27: ...IMM Installation Step 1 Unlock the DIMM socket by pressing the retaining clips outward Step 2 Insert the memory module into the slot Make sure that the DIMM notch is accurately positioned Step 3 Close...

Страница 28: ...18 Chapter 2 Hardware Setup SB302 LB User Manual Press the release button x 2 on the chassis Push the cover horizontally toward the rear panel Lift the cover upward to remove 2 3 Top Cover...

Страница 29: ...Removing the Power Supply Unit Press the latch to release the module Pull the handle to remove the module out of the chassis Push the replaced power supply unit into the chassis Ensure that the modul...

Страница 30: ...ubber connectors from the attached bracket Insert the replaced fan into the chassis Verify to align the rubber connectors with the appropriate slot in the bracket NOTE The fan should be blowing toward...

Страница 31: ...osen the lever Pull the tray lever outward completely Pull the tray out of the system Insert the hard disk drive into the tray Ensure that the dimples on the tray match the hard disk drive For additio...

Страница 32: ...eplacing the HDD Backplane Detach the cables and hard disk drives from the backplane module Dislodge the screws on the module Lift the module upward to remove Insert the replaced HDD backplane into th...

Страница 33: ...23 Chapter 2 Hardware Setup SB302 LB User Manual...

Страница 34: ...lot Cover Take the card and check for downside printedbord connectors Keep that connector side downward and either side in your hand Chek the position below 1 Locate the external connector side of car...

Страница 35: ...ser Manual Insert the card gently rolling in the side right between the edge of the motherboard and the wall of the Storage Server Barbone Press firmly to completely plug the card into the PCI slot an...

Страница 36: ...26 Chapter 2 Hardware Setup SB302 LB User Manual Check your earthing is working properly Turn on your Storage Server Barbone system detects new hardware...

Страница 37: ...Hardware Setup SB302 LB User Manual 2 9 1 Installing the RJ45 Module Remove PCI Bracket Slot Cover Take the RJ45 module insert onto the chassis Be sure the RJ45 module insert to chassis properly 2 9...

Страница 38: ...hapter 3 Hardware Settings Type v Press out additional flashing on the I O shield to make room for RJ45 module Align the module to the top and botton of the I O shield Secure the RJ45 module on the I...

Страница 39: ...SB302 LB User Manual 2 9 2 Configure the RJ45 Function Setting Insert one end of the cable into port LAN3 of the barebone Insert the other end of the cable into the corresponding port LAN4 on site of...

Страница 40: ...30 SB302 LB User Manual Chapter 3 Hardware Settings Release and detach the inner rail from the slide PUSH 2 10 Slide Rail Installation...

Страница 41: ...31 Chapter 3 Hardware Settings SB302 LB User Manual Attach inner rail to the system Click...

Страница 42: ...32 SB302 LB User Manual Chapter 3 Hardware Settings Attach outer rail to the rack Click Click PUSH u v...

Страница 43: ...33 Chapter 3 Hardware Settings SB302 LB User Manual Pull out the intermediate member until locked out NOTE Verify if the ball bearing retainer is locked forward u v...

Страница 44: ...34 SB302 LB User Manual Chapter 3 Hardware Settings Slide release tab and push system into rack u v...

Страница 45: ...ter 3 Hardware Settings SB302 LB User Manual This section describes the jumpers internal connectors and internal LEDs settings in the server barebone 3 1 Motherboard Block Diagram Chapter 3 Hardware S...

Страница 46: ...11 Serial ATA SATA1 SATA4 38 Flash Descriptor Security override J7 12 SSATA SATA5 SATA8 39 No Reboot Watch Dog J8 13 VGA Pin header JVGA_INT 40 NTB Non Transparent Bridge JNTB 14 COM Port JCOM4 41 PC...

Страница 47: ...PCH_GPIO JNGFF JINTRUDER JBMC_I2C1 JBMC_RST JBMC_DIS JLPC_DP JBMC_I2C10 JBUZZER JBMC_GPIO JDIMME0 JDIMME1 JDIMMF0 JDIMMF1 JCPU1 JCPU0 JDIMMH1 JDIMMH0 JDIMMG1 JDIMMG0 JDIMMC0 JDIMMC1 JDIMMD0 JDIMMD1 JD...

Страница 48: ...D 3 3V HD_LED SW_PWR_BTN LAN1_LINK_UP SYS_HEALTH 1 SYS_HEALTH 2 UIDLED_OUT 1 2 1 J17 JPG_LOCK1 JDIMME0 JDIMME1 JDIMMF0 JDIMMF1 JCPU1 JCPU0 JDIMMH1 JDIMMH0 JDIMMG1 JDIMMG0 JDIMMC0 JDIMMC1 JDIMMD0 JDIMM...

Страница 49: ...FP_USB3_TX_N2 PCH_FP_USB2_N2 PCH_FP_USB3_TX_P2 PCH_FP_USB2_P2 PCH_FP_USB2_N3 PCH_USB_OC 23 PCH_FP_USB2_P3 10 11 HM_TD8 HM_TD8 HM_TD7 HM_TD7 GND 12V FAN7_TACH PWM4 1 1 6 GND 12V FAN1_TACH PWM1 FAN1A_PR...

Страница 50: ...SGPIO JSGPIO JTPM J6 J7 J8 J9 DSRB DCDB RXDB CTSB RTSB 1 2 9 10 TXDB RIB GND DTRB KEY no pin 1 9 10 2 3 3V GND PCH_SPI_MISO PCH_SPI_CLK PCH_SPI_CS1_N PCH_SPI_CS2_N PCH_SPI_MOSI PCH_GPIO23 PCH_LDRQ0_N...

Страница 51: ...nstream port Open Upstream port Default MDI_N0 MDI_P1 MDI_N1 1V5_DUAL_LAN4 MDI_P0 1 2 9 10 GND MDI_N3 MDI_N2 MDI_P2 MDI_P3 MDI_N0 MDI_P1 MDI_N1 1 0V_PHY_I217 MDI_P0 1 2 9 10 GND MDI_N3 MDI_N2 MDI_P2 M...

Страница 52: ...ND GND CLK_33M_DP80 PCH_GPIO61 PCH_LFRAME_N AST_SERIRQ RST_PLTRST_N PCH_LPC_LAD2 PCH_LPC_LAD3 PCH_LPC_LAD1 PCH_LPC_LAD0 3 3V 1 2 11 12 SCOM2_T3OUT SCOM2_R4IN GND GND PCH_GPIO27 PCH_GPIO21 SW_PWR_BTN T...

Страница 53: ...SAS_EXP_RX_N6 C5 SAS_EXP_TX_N6 A6 GND C6 GND A7 SAS_EXP_RX_P7 C7 SAS_EXP_TX_P7 A8 SAS_EXP_RX_N7 C8 SAS_EXP_TX_N7 A9 GND C9 GND B1 GND D1 SIO1_SAS_DIN B2 SIO1_SAS_LOAD D2 NC B3 GND D3 GND B4 SAS_EXP_R...

Страница 54: ...28 NC 29 PERn1 30 NC 31 PERp1 32 NC 33 GND 34 NC 35 PETn1 36 NC 37 PETp1 38 DEVSLP I 0_3V3 39 GND 40 NC 41 PERn0_SATA B 42 NC 43 PERp0_SATA B 44 NC 45 GND 46 NC 47 PETn0_SATA A 48 NC 49 PETp0_SATA A 5...

Страница 55: ...NC JINTRUDER Setting Short Case Open OFF Enable Default 1 2 JBMC_DIS Setting Short Disable Open Normal Default SMB_PMBUS_CLK SMB_PMBUS_DATA PMBUS_ALERT_N GND 3 3V 1 5 BMC X540 I350 JINTRUDER JBMC_I2C1...

Страница 56: ...Off No disk activity is detected LAN1 Yellow Blinking LAN1 activity is detected LAN1 is not active Off LAN1 is not active System Error Red Critical system failure is detected processors memory voltage...

Страница 57: ...t Status LED 100M Green 10M No connection Off LAN 1 Right Green Blinking LAN1 activity is detected Off LAN1 is not active LAN cable is not connected LAN 1 Left Status LED 10G Green 1G Yellow 10M No co...

Страница 58: ...g BMC activity detected LED4 Off BMC is not active SYS PG LED On System power is ready LED2 Off System power is not ready RSMRST PG LED On Resume Well Reset is ready LED3 Off Resume Well Reset is not...

Страница 59: ...Placement 3 6 HDD Backplane JPWR1 JPWR1 JPWR2 JPWR2 JI2C3 JFAN1 JFAN1 JFAN2 JFAN2 JI2C4 JI2C4 JI2C0 JEXP2 JEXP_UART JEXP_UART JFAN3 JFAN3 JFAN4 JFAN4 JMCU_DBG JMCU_DBG JMCU_UART JMCU_UART JFRONT JFRON...

Страница 60: ...n Description 7 12V 1 GND 8 12V 2 GND 9 3 3V 3 GND 10 5V 4 MUTE_L 11 5VSTBY 5 PSU_N1 12 PS_ON_L 6 GND Power Connector JPWR2 Pin Description Pin Description 8 12V 1 GND 9 12V 2 GND 10 12V 3 GND 11 12V...

Страница 61: ...N A FAN Connector JFAN1 JFAN2 JFAN3 JFAN4 Pin Description 1 GND 2 I2C_CLOCK 3 I2C_DATA 4 N A Console for Expander JEXP_UART Pin Description Pin Description 2 DEBUG_RXD 1 SMART_RXD 4 12V 3 GND 6 DEBUG_...

Страница 62: ...ree Fan JFAN1 JFAN2 and JFAN3 Open Close Close Four Fan JFAN1 JFAN2 JFAN3 and JFAN4 Power Module Fault Input Pin Description Remark 7 GND 8 Power Fault Input Active Low AT Mode Setting Pin Description...

Страница 63: ...emark 17 GND 18 MUTE Input Active Low Power ID LED Pin Description Remark 19 For External LED LED Anode 20 For External LED LED Cathode Power SW Pin Description Remark 21 Power SW Input Active Low 22...

Страница 64: ...rmal Red Blinking Re build status Red On HDD Fault or Locate HDD RSAS HD Link Status Blue On Link up Blue Blinking Activity detected Off Link down Expander Blink LED5 Blue Blinking Expander alive 0 83...

Страница 65: ...3 6 4 Jumper JMCU_RST Open Normal default Close Reset MCU JMD_SEL Open Normal default Close Boot loader mode JMCU_RST JMCU_RST JMD_SEL JMD_SEL...

Страница 66: ...3 6 5 Drive Slot Map...

Страница 67: ...POST you have to restart the system by using one of the three methods Press Ctrl Alt Delete Press the reset button on the system chassis Turn the system off and on 4 1 Navigation Keys The navigation k...

Страница 68: ...ime Advanced Allows configuration of advanced system settings such as ACPI features boot and chipset configuration Security Sets passwords and security functions Power Configures Power Configurations...

Страница 69: ...ttings SB302 LB User Manual Step 2 There will be a message Entering SETUP displayed on the diagnostics screen NOTE For the official released version the last digit of the BIOS version must end in an 0...

Страница 70: ...62 SB302 LB User Manual Chapter 4 BIOS Configuration Settings Step 4 Load Optimal Default setting Step 5 Save the setting and exit the BIOS setup utility...

Страница 71: ...Settings SB302 LB User Manual Main Option Key 4 3 1 Main Option Key Description Language Configures the language used for your BIOS settings System time Configures the current time System date Config...

Страница 72: ...onfiguration Serial Port A Serial Port B Auto Enable Disable Serial Port C Auto Enable Disable Base I O Address 2E8 2F8 3E8 3F8 Interrupt IRQ3 IRQ4 Interrupt IRQ7 IRQ8 PCIe SR IOV Enable Disable PCIe...

Страница 73: ...Disable 4 4 3 PCH SSATA Configuration Configure sSATA device and settings PCH SATA Configuration sSATA Controller Enable Disable Configure sSATA as IDE AHCI RAID SATA Mode options Enable Disable Suppo...

Страница 74: ...able PCI E ASPM Support Global L1 Only Disable CLKRUN logic Enable Disable BIOS Lock Enable Disable After G3 On S0 S5 Last State 4 4 7 Processor Configuration Displays and provides option to change th...

Страница 75: ...tate Enable Disable Package C State limit C0 C1 state C2 state C6 non Retenti on state C6 Retenti on state No Limit CPU C3 report CPU C6 report Enable Disable CPU Thermal Management Bi directional PRO...

Страница 76: ...cket Min 0 Max 7 COD Enable Auto Enable Disable Early Snoop Auto Enable Disable QPI Per Socket Configuration CPU 0 CPU1 CPU 0 QPI Port 0 1 Link Disable Yes No Link Credit Reduce Yes No Current QPI Lin...

Страница 77: ...4 4 11 Memory Configuration Displays and provides option to change the Memory Settings Memory Configuration Enforce POR Auto Enforce POR Disable Enforce Stretch Goals PPR Type Hard PPR Soft PPR PPR Di...

Страница 78: ...and Scrub Enable Disable 4 4 12 IIO Configuration Displays and provides option to change the IIO Settings IIO Configuration EV DFX Features Enable Disable IIO0 Configuration IIO1 Configuration IOU2 II...

Страница 79: ...ort Definition Transparent Bridge NTB to NTB NTB to RP IOU0 IOU01 IOU2 Non Posted Prefetch Enable Disable IOAT Configuration Sck0 IOAT Config Sck1 IOAT Config DCA Enable Disable DMA Enable Disable No...

Страница 80: ...able Yes No Corrected Error Enable Enable Disable Uncorrected Error Enable Enable Disable Fatal Error Enable Enable Disable PCIe Correctable error threshold Min 0 Max 255 Enable SERR propagation Yes N...

Страница 81: ...upport Min 0 Max 255 Power Cycle Time Enable Disable Power Button Enable Disable Reset Button Enable Disable NMI Button Enable Disable Lan Port Configuration Dedicated Shared LAN Channel Number Min 0...

Страница 82: ...ity Option Key 4 5 1 Set Supervisor password Set Supervisor Password Install or change the password and the length of the password must be greater than one character Set Supervisor password Please typ...

Страница 83: ...1 Power Wake on PME Determines the action taken when the system power is off and the PCI Power Management Enable wake up event occurs Auto Wake on S5 Auto Wake on S5 By Day of Month or Fixed time of e...

Страница 84: ...crease the time to boot the system Quiet Boot Disables or enables booting in Text Mode Network Stack Network Stack Support Windows 8 BitLocker Unlock UEFI IPv4 IPv6 PXE Legacy OPROM PXE Boot Capabilit...

Страница 85: ...nual Boot Boot Type Dual Boot Type Legacy Boot Type UEFI Boot Type Quick Boot Enable Disable Quiet Boot Enable Disable Network Stack Enable Disable PXE Boot Capability Enable Disable USB Boot Enable D...

Страница 86: ...Chapter 5 BMC Configuration Settings BMC management port Insert Ethernet LAN cable into the BMC LAN port There are two methods to setup BMC IP 5 1 Method 1 Use the BIOS Setup BIOS SETUP Server Mgmt B...

Страница 87: ...anual Chapter 5 BMC Configuration Settings 5 2 Method 2 Use a Dos Tool Syscheck Type in sc lanset Modify the IP setting NOTE Type 1 for selecting static IP Mode and type 2 for selecting DHCP Mode Type...

Страница 88: ...hange the IP address for individual purposes Open the browser then type default BMC IP address 192 168 22 22 Use the default user name and password for first time login to BMC WEB UI Field Default Use...

Страница 89: ...iguration Settings 5 4 1 Dashboard The Dashboard page gives the overall information about the status of a device To open the Dashboard page click Dashboard from the menu bar A sample screenshot of the...

Страница 90: ...isplayed in this page is Basic Information Common Header Information Chassis Information Board Information and Product Information of the FRU device To open the FRU Information Page click FRU Informat...

Страница 91: ...ive widget for that particular sensor Event Log Events generated by the system will be logged here Double click on a record to see the description System Audit Logs This page displays logs of system a...

Страница 92: ...gure the System Event log information Images Redirection The page is used to configure the images into the BMC for redirection This can be done either by uploading a image into BMC as Local Media or m...

Страница 93: ...Mouse Mode Settings Redirection console mouse mode settings can be modified here NCSI Settings The following options are for configuring the channel number and package ID information for the NCSI inte...

Страница 94: ...on RADIUS Settings Check the box below to enable RADIUS authentication and enter the required information to access the RADIUS server Press the Save button to save your changes Configure Remote Sessio...

Страница 95: ...readable format System and Audit Log Settings Enable and configure logging of system events below Or you can enable disable logging of audit events Press the Save button to save your changes System Fi...

Страница 96: ...on Press the button to launch the redirection console and manage the server remotely Power Control and Status The current server power status is shown below To perform a power control operation select...

Страница 97: ...89 SB302 LB User Manual Chapter 5 BMC Configuration Settings Environmental setting Press ALT C for local and remote OS mouse control switching...

Страница 98: ...events that will trigger the auto video recording function of the KVM server Video Recording This page shows a list of available recorded video files on the BMC Select a video and click the Play Video...

Страница 99: ...ur device You can select specific configuration items to be preserved by clicking Enter Preserve Configuration Upon Restore Configuration the selected configuration items will be preserved while all t...

Страница 100: ...LB User Manual 5 4 8 Firmware Update Firmware Update Upgrade firmware of the device Press Enter Update Mode to put the device in update mode Image Transfer Protocol The following option allows you to...

Страница 101: ...aicipc com tw North California United States Address 48531 Warm Springs Boulvard Suite 404 Fremont CA 94539 United States Tel 1 510 573 6730 Fax 1 510 573 6729 Sales Email sales aicipc com Support Em...

Отзывы: