background image

•  Ensure that the voltage of the power source is within the specification on the label 

when connecting the equipment to the power outlet. The current load and output power 

of loads must be within the specification.

•  This equipment must be firmly connected to reliable grounding before usage. Pay 

special attention to power supplied other than direct connections, e.g. using of power 

strips.

•  Place the power cord out of the way of foot traffic. Do not place anything over the 

power cord. The power cord must be rated for the product, voltage and current marked 

on the product’s electrical ratings label. The voltage and current rating of the cord 

should be greater than the voltage and current rating marked on the product.

Pay attention to hardware maintenance.

Pay attention to hardware maintenance.

注意硬體維護

注意硬體維護。

注意硬体维护

注意硬体维护。

Обратите внимание на обслуживание оборудования.

Обратите внимание на обслуживание оборудования.

Besteed aandacht aan hardware-onderhoud.

Besteed aandacht aan hardware-onderhoud.

•  If the equipment is not used for a long time, disconnect the equipment from mains to 

avoid being damaged by transient over-voltage.

•  Module and drive bays must not be empty. They must have a dummy cover.

•  Never open the equipment without professional assistence. For safety reasons, only 

qualified service personnel should open the equipment.

•  If one of the following situations arise, the equipment should be checked and tested by 

service personnel:

1.  The power cord or plug is damaged.

2.  Liquid has penetrated the equipment.

3.  The equipment has been exposed to moisture.

4.  The equipment does not work well or will not work according to its user manual.

5.  The equipment has been dropped and/or damaged.

6.  The equipment has obvious signs of breakage.

7.  Please disconnect this equipment from the AC outlet before cleaning. Do not 

use liquid or detergent for cleaning. The use of a moisture sheet or cloth is 

recommended for cleaning.

CAUTION

The equipment intended for installation should be placed in Restricted Access Location.

CAUTION

There will be a risk of explosion if battery is replaced by an incorrect type. Dispose 

of used batteries according to the instructions. After performing any installation or 

servicing, make sure the enclosure is correct in position before turning on the power.

CAUTION

This unit may have more than one power supply. Disconnect all power sources before 

maintenance to avoid electric shock.

iii

Содержание RSC-2ETS

Страница 1: ...UM_RSC 2ETS_v1 3_030921 RSC 2ETS Rackmount Chassis User s Manual...

Страница 2: ...dule 7 2 3 Fan Module 8 2 3 1 Removing the Fan 8 2 3 2 Installing the Fan 9 2 4 Hard Disk Drive 10 2 5 HDD Backplane 12 2 5 1 Removing the HDD Backplane 12 2 5 2 Installing the HDD Backplane 14 2 6 Sl...

Страница 3: ...ase History Release Date Version Update Content October 2017 1 User s Manual release to public April 2019 1 1 Content update August 2020 1 2 logo update March 2021 1 3 Manual cover update Technical Su...

Страница 4: ...Copyright 2017 AIC Inc All Rights Reserved This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements...

Страница 5: ...e for compliance could void your authority to operate the equipment Disclaimer AIC shall not be liable for technical or editorial errors or omissions contained herein The information provided is provi...

Страница 6: ...mputer boards are highly sensitive to static electricity Before operating a board or integrated circuit touch an unpainted portion of the system unit chassis for a couple of seconds to discharge any s...

Страница 7: ...ty They must have a dummy cover Never open the equipment without professional assistence For safety reasons only qualified service personnel should open the equipment If one of the following situation...

Страница 8: ...ll layout of the product including the fundamental components of the rackmount chassis design specifications and noteworthy features Chapter 2 Hardware Setup This chapter displays an easy installation...

Страница 9: ...ents of the carton are damaged If any damage is found do not remove the components contact the dealer where the subsystem was purchased for further instructions Before continuing first unpack the subs...

Страница 10: ...steel Color Front Panel Black Cooling 3 x 80x38mm PWM low power consumption hot swap fans Power Supply 550W 1 1 redundant power supply PMBus 1 2 80 Platinum Expansion Slots Front Panel System power o...

Страница 11: ...Chapter 1 Product Features Front Panel 12 x 3 5 hotswap drive tray 1 x USB 3 0 port Power Button System Power LED System HDD Activity LED LAN LED System Alert LED ID LED ID button System Reset button...

Страница 12: ...oduct Features Rear Panel Option 1 2 x 2 5 External hot swap drive bays 700W 1 1 redundant PSU PMBus 1 2 80 Platinum 7 x PCIe 3 0 slots low profile Option 2 2 x 2 5 7mm SSD OS Option 3 2 x 2 5 15mm in...

Страница 13: ...5 Chapter 1 Product Features Major Components 3 x 80 x 38mm PWM low power consumption hot swap fans 3 x 80 x 38mm PWM low power consumption hot swap fans 12 W x 9 6 D ATX compliant system board...

Страница 14: ...chapter provides detailed instructions on hardware installation 1 Push the button on both sides 2 Push the top cover backward 3 Lift up the top cover from the enclosure Chapter 2 Hardware Setup 2 1 T...

Страница 15: ...7 Chapter 2 Hardware Setup Push the latch towards the handle on the module Pull the handle to remove it from the enclosure 2 2 Power Supply Unit Module 1 2...

Страница 16: ...rdware Setup 2 3 1 Removing the Fan Grab and remove the fan module from the fan slot 1 2 Pull the fan module up gently and take out the fan module by removing the rubbers out from the fan bar 2 3 Fan...

Страница 17: ...Hardware Setup 2 3 2 Installing the Fan Align the fan module and make sure insert 4 screws with the opening in the enclosure 2 Make sure the 4 rubbers and connector insert firmly while fan module is...

Страница 18: ...10 Chapter 2 Hardware Setup 1 Release a drive tray by pressing the unlock button 2 Pull out the HDD tray handle and slide out the HDD tray 2 4 Hard Disk Drive...

Страница 19: ...es on HDD match the dimples on HDD tray 5 HDD can also be screwed on HDD tray by reserve 2 screw holes at the bottom for optional screw mounting 6 Insert the drive tray into chassis HDD cage Make sure...

Страница 20: ...12 Chapter 2 Hardware Setup 2 5 1 Removing the HDD Backplane Unplug all connectors HDDs from HDD backplane 1 2 Release the lock pin 2 5 HDD Backplane...

Страница 21: ...13 Chapter 2 Hardware Setup Lift up and remove the blackplane to the a little bit up from hook then can get out...

Страница 22: ...14 Chapter 2 Hardware Setup 2 5 2 Installing the HDD Backplane 1 Align the backplane with the hooks and insert it into the enclosure firmly 2 Lock the backplane Follow the reverse order...

Страница 23: ...15 Chapter 2 Hardware Setup Release and detach the inner rail from the slide P U S H 1 2 6 Slide Rail...

Страница 24: ...16 Chapter 2 Hardware Setup Attach inner rail to the system Reserve screw hole Make sure spring lock firmly slide inner rail to lock 2...

Страница 25: ...17 Chapter 2 Hardware Setup Attach outer rail to the rack L O C K P U S H A L I G N 3...

Страница 26: ...18 Chapter 2 Hardware Setup Verify ball bearing retainer is locked forward Pull out the intermediate rail until locked out Slide release tab and push system into rack 4 5 6...

Страница 27: ...19 This chapter provides detailed instruction guide on hardware instruction 3 1 HDD Backplane 3 1 1 Placement PCBA Placement Chapter 3 Hardware Specification...

Страница 28: ...U_DBG JMCU_DBG JMCU_UART JMCU_UART JFRONT JFRONT JMCU_DBG JMCU_UART JFRONT JFAN4 JFAN3 JFAN3 JFAN3 SASHD3 SASHD3 SASHD3 JI2C0 JI2C4 JEXP_UART JEXP_UART JEXP_UART JEXP2 JFAN2 JFAN1 JI2C3 JPMBUS JPMBUS...

Страница 29: ...7 12V 1 GND 8 12V 2 GND 9 3 3V 3 GND 10 5V 4 MUTE_L 11 5VSTBY 5 PSU_N1 12 PS_ON_L 6 GND Power Connector JPWR2 PIN Description PIN Description 8 12V 1 GND 9 12V 2 GND 10 12V 3 GND 11 12V 4 GND 12 5V 5...

Страница 30: ...Connector JFAN1 JFAN2 JFAN3 JFAN4 PIN Description 1 GND 2 I2C_CLOCK 3 I2C_DATA 4 N A Console for Expander JEXP_UART PIN Description PIN Description 2 DEBUG_RXD 1 SMART_RXD 4 12V 3 GND 6 DEBUG_TXD 5 S...

Страница 31: ...JFAN1 JFAN2 and JFAN3 Open Close Close Four Fan JFAN1 JFAN2 JFAN3 and JFAN4 Power Module Fault Input PIN Description Remark 7 GND 8 Power Fault Input Active Low AT Mode Setting PIN Description Remark...

Страница 32: ...GND 18 MUTE Input Active Low Power ID LED PIN Description Remark 19 For External LED LED Anode 20 For External LED LED Cathode Power SW PIN Description Remark 21 Power SW Input Active Low 22 GND PMBU...

Страница 33: ...nking Re build status Red On HDD Fault or Locate HDD Remark Blue On Link up Blue Blinking Activity detected Off Link down Expander Blink LED1 Blue Blinking Expander alive 0 833Hz 12 seconds per cycle...

Страница 34: ...26 Chapter 3 Hardware Specifications 3 1 5 Jumper JMCU_RST Open Normal default Close Reset MCU JMD_SEL Open Normal default Close Boot loader mode JMCU_RST JMCU_RST JMCU_RST JMD_SEL JMD_SEL JMD_SEL...

Страница 35: ...27 Chapter 3 Hardware Specifications 3 1 6 Drive Slot Map...

Страница 36: ...ma russia aicipc com tw North California United States Address 48531 Warm Springs Boulvard Suite 404 Fremont CA 94539 United States Tel 1 510 573 6730 Sales Email sales aicipc com Support Email suppor...

Отзывы: