54
Chapter 3. Sub-system Configuration Setup
J4060-02 User Manual
3.6.5.6 How to enable/disable the enclosure alarm by your software (HUB only)
Enclosure control element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON CONTROL
SELECT
PRDFAIL
DISABLE RST SWAP
Reserved
1
RQST
IDENT
Reserved
2
POWER CYCLE
REQUEST
POWER CYCLE DELAY
3
POWER OFF DURATION
REQUEST
FAILURE
REQUEST
WARNING
The system alarm LED is used for the enclosure alarm and power alarm. The
"REQUEST FAILURE" and “REQUEST WARNING” for Enclosure are defined in the bit1,
byte3 and bit0, byte3 of the "Enclosure control element" in the SES specification.
Setting either bit can enable the enclosure alarm. Clearing both bits disables the
enclosure alarm. We use the software package "sg3_utils" on Linux for example, and
have a SAS HBA and a cable to connect your host with the expander.
(A) Show the device for AIC Expander Controller (canister)
$ sg_map -i
/dev/sg2 AIC 12G 4U60: Hub 0c29
(B) Enable the enclosure alarm
$ sg_ses --descriptor=EnclosureElement01 --set=3:1:1 /dev/sg2
or
$ sg_ses --descriptor=EnclosureElement01 --set=3:0:1 /dev/sg2
(C) Disable the enclosure alarm
$ sg_ses --descriptor=EnclosureElement01 --clear=3:1:1 /dev/sg2
and
$ sg_ses --descriptor=EnclosureElement01 --clear=3:0:1 /dev/sg2
Содержание JBOD Series
Страница 1: ...UM_J4060 02_v3 1_121619 J4060 02 12Gb s SAS JBOD Series User s Manual...
Страница 40: ...31 J4060 02 User Manual Chapter 3 Sub system Configuration Setup...
Страница 45: ...36 Chapter 3 Sub system Configuration Setup J4060 02 User Manual...
Страница 99: ...90 Chapter 4 BMC Configuration Settings J4060 02 User Manual 5 Processing 6 Update successful...
Страница 102: ...93 J4060 02 User Manual Chapter 4 BMC Configuration Settings...