3.6.4.3 Temperature Sensor Element
(A) Temperature Sensor Control Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON CONTROL
SELECT PRDFAIL DISABLE
RST
SWAP
Reserved
1
RQST
IDENT
RQST
FAIL
Reserved
2
Reserved
3
Reserved
(B) Temperature Sensor Status Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON STATUS
Reserved
PRDFAIL DISABLE
SWAP
ELEMENT STATUS CODE
1
IDENT
FAIL
Reserved
2
TEMPERATURE
3
Reserved
OT
FAILURE
OT
WARNING
UT
FAILURE
UT
WARNING
Field
Value
ELEMENT
STATUS CODE
OK: Everything is Ok
NON-CRITICAL: If either warning limit is exceeded
CRITICAL: If either failure limit is exceeded
FAIL
A warning or failure condition is detected
TEMPERATURE Temperature reading
OT FAILURE
Temperature has exceeded the failure high threshold value
OT WARNING Temperature has exceeded the warning high threshold value
UT FAILURE Temperature is below the failure low threshold value
UT WARNING Temperature is below the warning low threshold value
Содержание 12G SAS JBOD Series
Страница 1: ...UM_4060 03_v1_072219 J4060 03 12G SAS JBOD Series User s Manual...
Страница 38: ...29 J4060 03 User Manual Chapter 3 Sub system Configuration Setup...
Страница 44: ...35 J4060 03 User Manual Chapter 3 Sub system Configuration Setup...
Страница 49: ...40 Chapter 3 Sub system Configuration Setup J4060 03 User Manual...
Страница 105: ...96 Chapter 4 BMC Configuration Settings J4060 03 User Manual 5 Processing 6 Update successful...
Страница 108: ...99 J4060 03 User Manual Chapter 4 BMC Configuration Settings BMC console port BMC LAN port BMC console port BMC LAN port...