J4060-03 User Manual
Chapter 3. Sub-system Configuration Setup
3.6.4.2 Cooling Element
(A) Cooling Control Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON CONTROL
SELECT PRDFAIL DISABLE
RST
SWAP
Reserved
1
RQST
IDENT
Reserved
2
3
Reserved
RQST
FAIL
RQST ON
Reserved
REQUESTED SPEED CODE
Field
Value
RQST IDENT Please refer to section “SES Element Control Functions” for details.
REQUESTED
SPEED CODE
Please refer to section “SES Element Control Functions” for details.
(B) Cooling Status Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON STATUS
Reserved
PRDFAIL DISABLE SWAP
ELEMENT STATUS CODE
1
IDENT
Reserved
ACTUAL FAN SPEED (MSB)
2
ACTUAL FAN SPEED (LSB)
3
HOT
SWAP
FAIL
RQST ON
OFF
Reserved
ACTUAL SPEED CODE
Field
Value
ELEMENT
STATUS CODE
OK: Actual fan speed > 0
CRITICAL: The fan RPM can’t be detected or equal to 0.
IDENT
Applicable only for Cooling element 0
0: Enable the smart fan function
1: Disable the smart fan function
ACTUAL FAN
SPEED
Current fan RPM
FAIL
The fan RPM can’t be detected or equal to 0.
ACTUAL SPEED
CODE
Speed code level bases on current fan RPM.
Содержание 12G SAS JBOD Series
Страница 1: ...UM_4060 03_v1_072219 J4060 03 12G SAS JBOD Series User s Manual...
Страница 38: ...29 J4060 03 User Manual Chapter 3 Sub system Configuration Setup...
Страница 44: ...35 J4060 03 User Manual Chapter 3 Sub system Configuration Setup...
Страница 49: ...40 Chapter 3 Sub system Configuration Setup J4060 03 User Manual...
Страница 105: ...96 Chapter 4 BMC Configuration Settings J4060 03 User Manual 5 Processing 6 Update successful...
Страница 108: ...99 J4060 03 User Manual Chapter 4 BMC Configuration Settings BMC console port BMC LAN port BMC console port BMC LAN port...