background image

 

Possible values: 

5- 2678400 (5 - 2678400s) 
 
Default value: 3600(one hours). 
Parameter size: 4 [byte] 
 
Parameter No. 104 Setting time for sending meter report (current) 
The interval time of sending meter report (current) to associated device (Group Lifeline). 
 

Possible values: 

5- 2678400 (5 - 2678400s) 
 
Default value: 3600(one hours). 
Parameter size: 4 [byte] 
 

Parameter No.254 Enable/disable the configuration command 
Lock/unlock all configuration parameters. 
 
Possible values: 
0–Unlock. 
1 – Lock. 
Default 

value

: 0 

Parameter size: 1[byte] 
 

------------------------------------------------------------------------------------------ 

For more information, Welcome visit: www.leedarson.com. 
Mail to: 

 [email protected] 

LEEDARSON LIGHTING CO., LTD. 
XINGDA RD, XINGTAI INDUSTRIAL ZONE, CHANGTAI COUNTY, ZHANGZHOU,FUJIAN, 
363900, CHINA 

 

Содержание HA-ZW-5PAB

Страница 1: ...ters regardless of vendor to increase reliability of the network Smart Plug is also a security Z Wave device and supports the Over The Air OTA feature for the product s firmware upgrade If you want yo...

Страница 2: ...ht is blue when the device is turned off the light changes to red 2 TECHNICAL SPECIFICATIONS Power supply 230V 10 50Hz Rated load current 10A Power consumption 1 5W Power output 2300W Operational temp...

Страница 3: ...frame 2 To remove the product from the Z Wave network a Insert the Smart Plug to power socket the LED will follow the status on or off of its load s power level b Set the Z Wave network main controlle...

Страница 4: ...V2 COMMAND_CLASS_SWITCH_BINARY_V1 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 COMMAND_CLASS_TRANSPORT_SERVICE_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2...

Страница 5: ...ommand such as short pressing 2 Sending Meter Report 3 Sending Device Reset Locally 5 2 Basic Command Basic CC maps to Switch Binary CC 5 3 Configuration Command Smart Plug offers a wide variety of ad...

Страница 6: ...0 The function is disabled 1 Send Basic report 2 Send Basic report only when Load status is not changed by Z Wave Command Default value 1 Parameter size 1 byte Parameter No 04 LED Load indicator mode...

Страница 7: ...the parameters 101 104 to default Possible values 85 Parameter size 1 byte Parameter No 101 Setting time for sending meter report watt The interval time of sending meter report watt to associated devi...

Страница 8: ...ssible values 5 2678400 5 2678400s Default value 3600 one hours Parameter size 4 byte Parameter No 254 Enable disable the configuration command Lock unlock all configuration parameters Possible values...

Отзывы: